Point dose calculations using an analytical pencil beam kernel for IMRT plan checking.
نویسنده
چکیده
A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is different from the method used for the treatment plan. Our approach uses a convolution algorithm and an analytical pencil beam kernel with eight parameters. The model is intuitive and simple. At the same time, the method is so general that it can be applied to both step-and-shoot and sliding-window techniques. The results of applications to actual treatment plans show that the calculated total isocentre doses are accurate within +/-2% of planned doses for six-field prostate plans when calculation points are in a uniform dose region. Head and neck cases show a slightly larger difference than prostate cases. When calculation points are located in a region of high dose gradient, however, the difference could be greater than 5%.
منابع مشابه
Intensity modulated dose calculation with an improved experimental pencil-beam kernel.
PURPOSE This article presents an improved pencil-beam dose calculation formalism based on an experimental kernel obtained by deconvolution. The new algorithm makes it possible to calculate the absorbed dose for all field sizes. METHODS The authors have enhanced their previous work [J. D. Azcona and J. Burguete, Med. Phys. 35, 248-259 (2008)] by correcting the kernel tail representing the cont...
متن کاملA system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution.
The number of intensity modulated radiation therapy (IMRT) procedures is continuously growing worldwide and it is necessary to develop tools for patient specific quality assurance (QA) that avoid using machine time that could be employed in treating additional patients. One way of achieving this goal is to perform a multileaf collimator quality assurance periodically in the linear accelerator a...
متن کاملEvaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms
Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...
متن کاملThe effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT
Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans. Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...
متن کاملDosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study
Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...