Moving GLM ballistocardiogram artifact reduction for EEG acquired simultaneously with fMRI.

نویسندگان

  • Justin L Vincent
  • Linda J Larson-Prior
  • John M Zempel
  • Abraham Z Snyder
چکیده

OBJECTIVE Simultaneous acquisition of electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) enables studies of brain activity at both high temporal and high spatial resolution. However, EEG acquired in a magnetic field is contaminated by ballistocardiogram (BKG) artifact. The most commonly used method of BKG artifact reduction, averaged artifact subtraction (AAS), was not designed to account for overlapping BKG waveforms generated by adjacent beats. We describe a new method based on a moving general linear model (mGLM) that accounts for overlapping BKG waveforms. METHODS Simultaneous EEG-fMRI at 3 Tesla was performed in nine normal human subjects (8-11 runs/subject, 5.52 min/run). Gradient switching artifact was effectively reduced using commercially supplied procedures. Cardiac beats were detected using a novel correlation detector algorithm applied to the EKG trace. BKG artifact was reduced using both mGLM and AAS. RESULTS mGLM recovered BKG waveforms outlasting the median inter-beat interval. mGLM more effectively than AAS removed variance in the EEG attributable to BKG artifact. CONCLUSIONS mGLM offers advantages over AAS especially in the presence of variable heart rate. SIGNIFICANCE The BKG artifact reduction procedure described herein improves the technique of simultaneous EEG-fMRI. Potential applications include basic investigations of the relationship between scalp potentials and functional imaging signals as well as clinical localization of epileptic foci.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI.

Electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are now being combined to analyze brain function. Confounding the EEG signal acquired in the MR environment is a ballistocardiogram artifact (BA), which is predominantly caused by cardiac-related body movement. The objective of this study was to develop and evaluate a method for reducing these MR-induced artifacts to ...

متن کامل

Artifact reduction for EEG/fMRI recording part 1: nonlinear reduction of ballistocardiogram artifact

Objective: We present a new method to effectively remove ballistocardiogram artifacts (BAs) of electroencephalography (EEG), recorded inside a 1.5 T static magnetic field scanner, and conserve the time and frequency features of EEG activity. Methods: The BAs are approximated as deterministically chaotic dynamics. A wavelet-based nonlinear noise reduction (WNNR) method consisting of wavelet tran...

متن کامل

Removing ballistocardiogram (BCG) artifact from full-scalp EEG acquired inside the MR scanner with Orthogonal Matching Pursuit (OMP)

Ballistocardiogram (BCG) artifact remains a major challenge that renders electroencephalographic (EEG) signals hard to interpret in simultaneous EEG and functional MRI (fMRI) data acquisition. Here, we propose an integrated learning and inference approach that takes advantage of a commercial high-density EEG cap, to estimate the BCG contribution in noisy EEG recordings from inside the MR scanne...

متن کامل

ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner.

Electroencephalogram (EEG) data acquired in the MRI scanner contains significant artifacts, one of the most prominent of which is ballistocardiogram (BCG) artifact. BCG artifacts are generated by movement of EEG electrodes inside the magnetic field due to pulsatile changes in blood flow tied to the cardiac cycle. Independent Component Analysis (ICA) is a statistical algorithm that is useful for...

متن کامل

Real-time EEG artifact correction during fMRI using ICA

BACKGROUND Simultaneous acquisition of EEG and fMRI data results in EEG signal contamination by imaging (MR) and ballistocardiogram (BCG) artifacts. Artifact correction of EEG data for real-time applications, such as neurofeedback studies, is the subject of ongoing research. To date, average artifact subtraction (AAS) is the most widespread real-time method used to partially remove BCG and imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 118 5  شماره 

صفحات  -

تاریخ انتشار 2007