Basic requirements for monitoring sedated patients: blood pressure, pulse oximetry, and EKG.
نویسندگان
چکیده
The American Society of Anesthesiologists published monitoring requirements for non-anesthesia providers performing sedation and analgesia in 2002. This manuscript covered not only the monitoring of patients under sedation and analgesia but pre-procedure evaluation and preparation, personnel availability and training, emergency equipment availability, use of supplemental oxygen, sedative-analgesic agents, and discharge criteria. Current recommendations for monitoring include patient responsiveness, blood pressure, respiratory rate, heart rate, and oxygen saturation. Oxygen saturation is a critical vital sign, but there can be a significant delay between inadequate ventilation and desaturation. Supplemental oxygen can dangerously increase this disconnect. Thus, one must monitor adequacy of ventilation by direct observation, auscultation, and/or end-tidal CO(2) monitoring. The most important admonition is that 'ventilation' and 'oxygenation' are not the same.
منابع مشابه
The role of sedation and pulse oximetry during upper gastrointestinal endoscopy.
INTRODUCTION To determine the changes in oxygen saturation, blood pressure and pulse rate during endoscopic procedure and to evaluate--oesophagogastroduodenoscopy (OGD) related discomfort assessed by the patient. METHODS It is observational case control study. Baseline pulse, blood pressure and oxygen saturation were monitored before procedure, at one minute of procedure, at five minute and s...
متن کاملPulse oximetry monitoring during non-sedated upper gastrointestinal endoscopy.
Fifty consecutive patients judged fit for non-sedated upper gastrointestinal endoscopy were monitored by pulse oximetry before, during and after the procedure. Transient hypoxia developed during intubation in five subjects (10%) but treatment was not required nor was the test halted. Only one patient with pre-existing respiratory problems became hypoxaemic to the extent that oxygen had to be gi...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملAn investigation of capnography and pulse oximetry as monitors of pediatric patients sedated for dental treatment.
Traditional methods of monitoring sedated pediatric dental patients have major shortcomings. This study evaluated the use of capnography in conjunction with pulse oximetry for monitoring children during conscious sedation for dental treatment. The specific purposes of the study were to determine if capnography would: (1) detect ventilatory changes that subsequently cause an oxyhemoglobin desatu...
متن کاملCombined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip.
BACKGROUND We compared the accuracy and practicability of a new combined ear sensor device measuring pulse oximetry and transcutaneous carbon dioxide tension. METHODS Validation studies were done by comparing the results of the combined sensor with arterial blood gas measurements. In an observational part, monitoring data were obtained from 25 patients undergoing colonoscopy, sedated with mid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Digestion
دوره 82 2 شماره
صفحات -
تاریخ انتشار 2010