Functional optical zone of the cornea.
نویسندگان
چکیده
PURPOSE When keratorefractive surgery is used to treat a central corneal diameter smaller than the resting pupil, visual symptoms of polyopia, ghosting, blur, haloes, and glare can be experienced. Progress has been made to enlarge the area of surgical treatment to extend beyond the photopic pupil; however, geometric limitations can pose restrictions to extend the treatment beyond the mesopic pupil diameter and can lead to impediments in night vision. The size of the treated area that has achieved good optical performance has been defined as the functional optical zone (FOZ). In this study the authors developed three objective methods to measure the FOZ. METHODS Corneal topography examination results from 1 eye of 34 unoperated normal eyes and 32 myopic eyes corrected by laser in situ keratomileusis (LASIK) were evaluated in three ways. First, a uniform axial power method (FOZ(A)) assessed the area of the postoperative cornea that was within a +/-0.5-D window centered on the mathematical mode. Second, FOZ was determined based on the corneal wavefront true RMS error as a function of the simulated pupil size (FOZ(R)). Third, FOZ was determined from the radial MTF, established at the retinal plane as a function of pupil size (FOZ(M)). RESULTS Means for each of the FOZ methods (FOZ(A), FOZ(R), and FOZ(M)) were 7.6, 9.1, and 7.7 mm, respectively, for normal eyes. For LASIK-corrected eyes, these means were 6.0, 6.9, and 6.0 mm. Overall, an average decrease of 1.8 mm in the functional optical zone was found after the LASIK procedure. Correlations between the FOZ methods after LASIK showed acceptable and statistically significant values (R = 0.71, 0.70, and 0.61; P < 0.01). CONCLUSIONS These methods will be useful to more fully characterize corneal treatment profiles after keratorefractive surgery. Because of its ease of implementation, direct spatial correspondence to corneal topography, and good correlation to the other more computationally intensive methods, the semiempiric uniform axial power method (FOZ(A)) appears to be most practical in use. The ability to measure the size of the FOZ should permit further evolution of keratorefractive surgical lasers and their algorithms to reduce the night vision impediments that can arise from functional optical zones that do not encompass the entire mesopic pupil.
منابع مشابه
A three-dimensional optical model to describe the optical function of the keratoconus eye
This article has no abstract.
متن کاملThe assessment of the stability of the corneal structure after LASIK correction of myopia by different optical zone diameters Procena stabilnosti strukture rožnjače nakon korekcije kratkovidosti metodom LASIK sa različitim prečnicima optičke zone
Background/Aim. Enlargement of optical zone (OZ) diameter during laser in situ keratomileusis (LASIK) correction of myopia postoperatively improves the optical outcome, however, it also leads to the increased stroma tissue consumption – progressive corneal thinning. The aim of this investigation was to present the possibility of safe OZ enlargement without impairing the structural stability of ...
متن کاملToday’s PracTice refracTive fundamenTals
MyOPiC LASer COrreCtiOn The most popular type of laser correction for myopia is LASIK. Myopic laser correction is achieved by central corneal ablation, which reduces the refractive power of the anterior corneal surface. Myopic LASIK has been shown to be effective in correcting low to moderate myopia.1,2 LASIK correction of high myopia has been fraught with quality issues until recently. Factors...
متن کاملFirst-Principles Study of Structure, Electronic and Optical Properties of HgSe in Zinc Blende (B3) Phase
In this paper, the structural parameters, energy bands structure, density ofstates and charge density of HgSe in the Zincblende(B3) phase have been investigated.The calculations have been performed using the Pseudopotential method in theframework of density functional theory (DFT) by Quantum Espresso package. Theresults for the electronic density of states (DOS) show tha...
متن کاملHalogenated Graphdiyne and Graphyne Single Layers: A Systematic Study
Graphyne and graphdiyne families of flat carbon (sp2/sp) networks with high degrees of π-conjunction are attracting much attention due to their promising electronic, optical, and mechanical properties. In the present investigation we have studied the structural, mechanical, electrical and optical properties of halogenated graphdiyne and graphyne. The optical spectra of pure and halog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 48 3 شماره
صفحات -
تاریخ انتشار 2007