Bilateral Comparison of Dc Voltage References between Cenam and Nist

نویسندگان

  • Yi-hua Tang
  • Dionisio Hernández
  • Enrique Navarrete
چکیده

A comparison of Josephson Voltage Standards (JVS) between the National Institute of Standards and Technology (NIST) and the Centro Nacional de Metrología (CENAM) held at CENAM from 21 to 23 of March 2006 is reported. The comparison was made at the 10 V level by measuring four Zener references using the JVS of CENAM and the transportable Compact Josephson Voltage Standard (CJVS) of NIST. The difference between the measurements was -34.7 nV with an uncertainty of 43.2 nV at 95 % level of confidence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Josephson Voltage Standards Comparison between Cenam and Nist at 10 V Level

Abstract: A comparison of Josephson Voltage Standards (JVS) between the National Institute of Standards and Technology (NIST) and the Centro Nacional de Metrología (CENAM) held at CENAM from 21 to 23 of March 2006 is reported. The comparison was made at the 10 V level by measuring four Zener references using the JVS of CENAM and the transportable Compact Josephson Voltage Standard (CJVS) of NIS...

متن کامل

Bilateral Optical Power Meter Comparison Between NIST and CENAM*

We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Centro Nacional De Metrología (CENAM-Mexico). Open beam (free field) and optical-fiber-based measurements at wavelengths of 1302 nm and 1546 nm are reported. Both laboratories' reference standards were compared by means of a temperature-controlled optical trap...

متن کامل

Status Report to CCEM of Electrical Metrology Developments at NIST

NIST researchers advanced the measurement and automation capabilities of quantum-based dc and ac programmable Josephson voltage standards (PJVS) such that the NIST PJVS is now capable of providing ac voltage measurements through differential sampling at voltages up to 10 V and frequencies up to 400 kHz. New automation software and hardware were implemented. Measurements of leakage resistance we...

متن کامل

The Calibration of dc Voltage Standards at NIST

This document describes the procedures used at NIST to calibrate dc voltage standards in terms of the NIST volt. Three calibration services are offered by the Electricity Division: Regular Calibration Service (RCS) of client standard cells at NIST; the Volt Transfer Program (VTP) a process to determine the difference between the NIST volt and the volt as maintained by a group of standard cells ...

متن کامل

DIFFERENTIAL PRESSURE COMPARISON FROM 20 Pa TO 3 500 Pa BETWEEN CEM - SPAIN AND CENAM - MEXICO

− The results of a comparison in differential pressure between CEM-Spain and CENAM-Mexico are presented here. The comparison was performed in 2008. A high accuracy digital manometer was used for the comparison. The manometer had good behaviour during the period of the comparison, having a small drift which had no effect in the comparison. The results of the measurements showed very good agreeme...