Serological evaluation of thin-layer immunoassay-enzyme-linked immunosorbent assay for antibody detection in human trichinellosis.
نویسندگان
چکیده
A new immunoenzymatic test, named the thin-layer immunoassay-enzyme-linked immunosorbent assay (TIA-ELISA), was evaluated for antibody detection in human trichinellosis using excretion and secretion products prepared from Trichinella spiralis muscle larvae. Serum samples from people with positive muscle biopsies or symptoms compatible with the disease (n = 8 or 26, respectively), all reactive in enzyme-linked immunoelectrotransfer blot assay (EITB), as well as 67 serum samples from healthy, EITB-negative people, were tested in an ELISA and TIA-ELISA. TIA-ELISA was performed in polystyrene plastic petri dishes by adding dots of 10 microl each of antigen (7 microg/ml) followed by adding diluted serum and the conjugate. Finally, the substrate mixed with agar was added to develop the reaction. Enzymatic by-products were easily detected by the naked eye as defined dots. Sensitivity and specificity were 76 and 94% for ELISA, and both parameters were 91% for TIA-ELISA. The kappa correlation indices for both tests in relation to EITB were 0.73 and 0.80, respectively. The TIA-ELISA can be carried out with common laboratory equipment in 3 h and uses lower quantities of antigen than EITB and ELISA. Since TIA-ELISA is easy to perform, cheap, sensitive, and specific, the test could be an acceptable alternative to use in clinical laboratories lacking specialized equipment needed for ELISA and EITB and in field studies for antibody detection in human trichinellosis.
منابع مشابه
Evaluation of Enzyme Linked Immunosorbent Assay, Utilizing Native Antigen B for Serodiagnosis of Human Hydatidosis
Background: Hydatidosis is one of the cosmopolitan parasitic zoonoses caused by the larval stage of Echinococcus granulosus. Diagnosis of hydatidosis is still an unresolved problem. Serological tests using crude antigens for diagnosis of E. granulosus are sensi-tive, however their specificity are not satisfactory. Therefore, WHO recommended spe-cific serological methods using specific antigens,...
متن کاملStandardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.
An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...
متن کاملProduction and Evaluation of Polyclonal Rabbit Anti-Human p53 Antibody Using Bacterially Expressed Glutathione S-transferase-p53 fusion protein
p53 is a key tumor suppressor gene that is targeted for inactivation during human tumorigenesis. In this study, we produced and characterized polyclonal antihuman p53 antibody. The cDNA encoding the completehuman p53 protein was cloned into pGEX-4T-1 and expressed in Escherichia coli as a fusion protein with Schistosoma japonicum glutathione S-transferase (GST). The rabbits were immunized...
متن کاملDesigning an enzyme-linked immunosorbent assay for detection of anti-penicillin antibodies levels in various species of animals in Khuzestan province, Iran
The penicillin allergy is being increasingly recognized as a significant public health problem. Immunological responses to penicillin and other beta-lactam antibiotics are classified as immediate and non-immediate responses. This research aimed to develop an enzyme-linked immunosorbent assay (ELISA) for the detection of the reactive antibody value against penicillin in various species of animals...
متن کاملComparison of four techniques for detection of antibodies to cytomegalovirus.
Four serological methods were compared and evaluated for use in detecting cytomegalovirus antibody in blood and organ donors. Western blotting (immunoblotting), latex agglutination, enzyme-linked immunosorbent assay, and a recent available microparticle enzyme immunosorbent assay were used. The microparticle enzyme immunoassay appears to compare favorably with each of the other three assays tes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical and diagnostic laboratory immunology
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2000