Computerized method of visual acuity testing: adaptation of the amblyopia treatment study visual acuity testing protocol.
نویسندگان
چکیده
PURPOSE To report a computerized method for determining visual acuity in children using the Amblyopia Treatment Study visual acuity testing protocol. METHODS A computerized visual acuity tester was developed that uses a programmed handheld device that uses the Palm operating system (Palm, Inc, Santa Clara, California). The handheld device communicates with a personal computer running a Linux operating system and 17-inch monitor. At a test distance of 3 m, single letters can be displayed from 20/800 to 20/12. A C program on the handheld device runs the Amblyopia Treatment Study visual acuity testing protocol. Using this method, visual acuity was tested in both the right and left eyes, and then the testing was repeated in 156 children age 3 to 7 years at four clinical sites. RESULTS Test-retest reliability was high (r =.92 and 0.95 for and right and left eyes, respectively), with 88% of right eye retests and 94% of left eye retests within 0.1 logarithm of minimal angle of resolution (logMAR) units of the initial test. The 95% confidence interval for an acuity score was calculated to be the score +/- 0.13 logMAR units. For a change between two acuity scores, the 95% confidence interval was the difference +/- 0.19 logMAR units. CONCLUSIONS We have developed a computerized method for measurement of visual acuity. Automation of the Amblyopia Treatment Study visual acuity testing protocol is an effective method of testing visual acuity in children 3 to 7 years of age.
منابع مشابه
Visual Acuity Before and After Occlusion Therapy in Children and Adolescents (Aged 5-13 years) Amblyopia
Purpose: To evaluate the effect of occlusion therapy on visual acuity in children and adolescents (aged 5-13 years) with amblyopia. Methods: This experimental study followed a pretest-posttest design. Totally, 72 people with amblyopic eyes (visual acuity between 20/100 and 20/25) were selected through convenient sampling. The visual acuity was assessed at 1, 3, and 6 months after starting occlu...
متن کاملA computerized method of visual acuity testing: adaptation of the early treatment of diabetic retinopathy study testing protocol.
PURPOSE To develop a computerized method of visual acuity testing for clinical research as an alternative to the standard Early Treatment for Diabetic Retinopathy Study (ETDRS) testing protocol, and to evaluate its test-retest reliability and concordance with standard ETDRS testing. DESIGN Test-retest reliability study. METHODS Multicenter setting of a study population of 265 patients at th...
متن کاملSIGMA: A Serious Game Based on a New Approach to Improving Visual Acuity in Children with Laze Eye(Amblyopia)
Background and Aim: One of the main reasons of blindness, Unilateral vision weakness in children, adolescents and middle aged people is Amblyopia. The goal of this project is to design and production of a serious game to treating Amblyopia and to investigate the effects of this method in children's. Materials and Methods: In this Interactive analysis, 60 people suffering from Unilateral Amblyo...
متن کاملتاثیر تحریکات بینایی CAM همراه با روش متداول اکلوژن در درمان کودکان آمبلیوپ: کارآزمایی بالینی تصادفی
Background: The application of CAM visual stimulation returns to the date of more than fifty years ago. However, the reports of previous studies in this field vary from no effect to significant effects of this method in amblyopia treatment. The purpose of this study was to determine the effect of CAM visual stimulation along with conventional occlusion therapy in anisometropic amblyopic childre...
متن کاملThe accuracy of the amblyopia treatment study visual acuity testing protocol.
PURPOSE To study the accuracy of the newly proposed Amblyopia Treatment Study (ATS) visual acuity testing protocol for 3- to 6-year-old children. Because no "gold standard" is available for acuity testing in pediatric patients, accuracy was evaluated using computer simulations based on a psychometric model. METHODS Monte Carlo simulations of ATS acuity data were generated using a psychometric...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of ophthalmology
دوره 132 6 شماره
صفحات -
تاریخ انتشار 2001