WE-G-WAB-01: Real-Time Catheter Tracking and Visualization in MR-Guided Brachytherapy.

نویسندگان

  • W Wang
  • Y Gao
  • A Mehrtash
  • R Seethmaraju
  • T Kapur
  • A Vishwanathan
  • E Schmidt
  • R Cormack
چکیده

PURPOSE The challenge of catheter-tip visualization for interstitial needle placement in gynecologic brachytherapy remains unmet. We evaluate an approach to actively track tip locations and visualize catheter trajectories and surrounding soft-tissue in real-time during an intervention. The methods include development of clinical needles with magnetic resonance (MR) tracked microcoils, an MR tracking and rapid imaging sequence and integration with a graphical workstation for visualization. METHODS An active tracking device was built based on a commercial catheter which consists of a hollow tube and a central needle with microcoils at the distal end. An MR tracking sequence was developed (isotropic resolution: 0.6 mm, frame rate: 40 updates/sec). It runs continuously during navigation or interleaves with real-time imaging (3 frames/sec), where image position/orientation are automatically set to provide visualization of anatomy around the catheter. The catheter-tip position/orientation was passed to the workstation for visualization. Needle shapes were superimposed on pre-acquired high-resolution images or on the intra-procedural images. RESULTS MR-guided catheter placement procedures were conducted in a gel phantom and an animal model. High-resolution 3D MR scans were acquired and loaded into the workstation for navigation. During insertion, the catheter tips were visualized advancing on a 3D anatomic model and on assigned planes. Real-time imaging with slice continuously updating at the instantaneous tip positions was also performed. Both methods served well to guide catheter placement. After insertion, complete catheter trajectories were rendered by recording tip positions as needles were pulled out and overlaid on the images, to support treatment planning. CONCLUSION We demonstrated the feasibility of active catheter tracking and visualization in MR-guided brachytherapy. This will facilitate accurate and time-efficient catheter insertion by providing on-line identification of catheter position, and visualization of anatomy ahead of the catheter tip. This enables identifying preferential paths to target locations, and reduces the risk to critical organs. FUNDING SOURCES NIH P41 EB015898; AHA 10SDG261039.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time active MR-tracking of metallic stylets in MR-guided radiation therapy.

PURPOSE To develop an active MR-tracking system to guide placement of metallic devices for radiation therapy. METHODS An actively tracked metallic stylet for brachytherapy was constructed by adding printed-circuit micro-coils to a commercial stylet. The coil design was optimized by electromagnetic simulation, and has a radio-frequency lobe pattern extending ∼5 mm beyond the strong B0 inhomoge...

متن کامل

Tracking Planar Orientations of Active Interventional Devices for Realtime Image Guided Procedures

S. Sathyanarayana, P. Aksit, A. Arepally, P. Karmarkar, M. Solaiyappan, E. Atalar Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland, United States, Global Applied Science Laboratory, GE Healthcare, Milwaukee, Wisconsin, United States, Radiology, Johns Hopkins Medical Institutes, Baltimore, Maryland, United States, Electrical and Computer Engineering, Bilkent Uni...

متن کامل

Multifunctional interventional devices for MRI: a combined electrophysiology/MRI catheter.

The design and application of a two-wire electrophysiology (EP) catheter that simultaneously records the intracardiac electrogram and receives the MR signal for active catheter tracking is described. The catheter acts as a long loop receiver, allowing for visualization of the entire catheter length while simultaneously behaving as a traditional two-wire EP catheter, allowing for intracardiac el...

متن کامل

Preclinical Evaluation of an MR-EP Suite including an MR-EP Navigator and Dedicated MR-EP Catheters

Introduction: Cardiac arrhythmias, e.g. atrial fibrillation and ventricular tachycardia, are increasingly treated by electrophysiological (EP) interventions [1]. Applying MR for guiding these interventions offers advantages like 3D visualization of the cardiac soft tissue in relation to the catheter, visualization of the treatment effect and absence of ionizing radiation [2,3]. The step towards...

متن کامل

3D MRI-guided Passive Catheter Tracking and Visualization using HYPR-based Techniques

INTRODUCTION Catheter tracking and visualization require both good spatial and temporal resolution. Achieving simultaneously both high temporal and spatial resolution is extremely difficult with current methods that use Cartesian k-space acquisition employing phase encoding. To date, passive device tracking and visualization techniques have typically been limited to two dimensions [1-2]. This i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 40 6Part30  شماره 

صفحات  -