Coagulation function of stored whole blood is preserved for 14 days in austere conditions: A ROTEM feasibility study during a Norwegian antipiracy mission and comparison to equal ratio reconstituted blood.

نویسندگان

  • Geir Strandenes
  • Ivar Austlid
  • Torunn O Apelseth
  • Tor A Hervig
  • Jan Sommerfelt-Pettersen
  • Maryanne C Herzig
  • Andrew P Cap
  • Heather F Pidcoke
  • Einar K Kristoffersen
چکیده

BACKGROUND Formulation of a medical preparedness plan for treating severely bleeding casualties during naval deployment is a significant challenge because of territory covered during most missions. The aim of this study was to evaluate the concept of "walking blood bank" as a supportable plan for supplying safe blood and blood products. METHODS In 2013, the Royal Norwegian Navy conducted antipiracy operations from a frigate, beginning in the Gulf of Aden and ending in the Indian Ocean. Crews were on 24-hour emergency alert in preparation for an enemy assault on the frigate. Under an approved command protocol, a "walking blood bank," using crew blood donations, was established for use on board and on missions conducted in rigid-hulled inflatable boats, during which freeze-dried plasma and leukoreduced, group O low anti-A/anti-B titer, cold-stored whole blood were stored in Golden Hour Boxes. Data demonstrating the ability to collect, store, and provide whole blood were collected to establish feasibility of implementing a whole blood-focused remote damage-control resuscitation program aboard a naval vessel. In addition, ROTEM data were collected to demonstrate feasibility of performing this analysis on a large naval vessel and to also measure hemostatic efficacy of cold-stored leukoreduced whole blood (CWB) stored during a period of 14 days. ROTEM data on CWB was compared with reconstituted whole blood. RESULTS Drills simulating massive transfusion activation were conducted, in which 2 U of warm fresh whole blood with platelet sparing leukoreduction were produced in 40 minutes, followed by collection of two additional units at 15-minute increments. The ROTEM machine performed well during ship-rolling, as shown by the overlapping calculated and measured mechanical piston movements measured by the ROTEM device. Error messages were recorded in 4 (1.5%) of 267 tests. CWB yielded reproducible ROTEM results demonstrating preserved fibrinogen function and platelet function for at least 3.5 weeks and 2 weeks, respectively. The frequency of ROTEM tests were as follows: EXTEM (n = 88), INTEM (n = 85), FIBTEM (n = 82), and APTEM (n = 12). CWB results were grouped. Compared with Days 0 to 2, EXTEM maximum clot firmness was significantly reduced, beginning on Days 10 to 14; however, results through that date remained within reference ranges and were comparable with the EXTEM maximum clot firmness for the reconstituted whole blood samples containing Day 5 room temperature-stored platelets. CONCLUSION A "walking blood bank" can provide a balanced transfusion product to support damage-control resuscitation/remote damage-control resuscitation aboard a frigate in the absence of conventional blood bank products. ROTEM analysis is feasible to monitor damage-control resuscitation and blood product quality. ROTEM analysis was possible in challenging operational conditions. LEVEL OF EVIDENCE Therapeutic study, level V.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional capacity of reconstituted blood in 1:1:1 versus 3:1:1 ratios: A thrombelastometry study

INTRODUCTION Different transfusion ratio concepts of packed red blood cells (pRBCs), fresh frozen plasma (FFP) and platelets (PLTs) have been implemented in trauma care, but the optimal ratios are still discussed. In this study the hemostatic potential of two predefined ratios was assessed by using an in vitro thrombelastometric approach. Furthermore, age effects of reconstituted blood were ana...

متن کامل

Alternation in Erythrocyte Enzyme Antioxidant Activity during Blood Storage

Background: Blood is permanently exposed to oxidation stress and therefore has a high antioxidants capacity. Many different factors increasing the demand for the antioxidant capacity can be observed in the stored blood of donors. Consequently, damage to erythrocytes by free radicals may occur. So it is useful to control the alternation of anti-oxidant enzymes in stored blood at different days o...

متن کامل

تاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکت‌ها در فراورده‌های پلاکتی

 Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...

متن کامل

The Alterations of Plasma Iipid Peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase Enzyme Activities During Storage of Blood

Abstract Background and objective: Exposure of red blood cells to oxygen radicals can induce Lipid proxidation, hemoglobin damage and hemolysis of erythrocyte .The present study was designed to determine the alteration of plasma lipid peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase enzyme activities in stored blood and to find out the quantitative alterations and th...

متن کامل

Emergency whole-blood use in the field: a simplified protocol for collection and transfusion.

Military experience and recent in vitro laboratory data provide a biological rationale for whole-blood use in the treatment of exsanguinating hemorrhage and have renewed interest in the reintroduction of fresh whole blood and cold-stored whole blood to patient care in austere environments. There is scant evidence to support, in a field environment, that a whole blood-based resuscitation strateg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of trauma and acute care surgery

دوره 78 6 Suppl 1  شماره 