Biomechanical stability of a bioabsorbable self-retaining polylactic acid/nano-sized β-tricalcium phosphate cervical spine interbody fusion device in single-level anterior cervical discectomy and fusion sheep models

نویسندگان

  • Lu Cao
  • Ping-Guo Duan
  • Xi-Lei Li
  • Feng-Lai Yuan
  • Ming-Dong Zhao
  • Wu Che
  • Hui-Ren Wang
  • Jian Dong
چکیده

PURPOSE The aim of this study was to investigate the biomechanical stability provided by a novel, polylactic acid/nano-sized, β-tricalcium phosphate, bioabsorbable, self-retaining cervical fusion cage (BCFC). METHODS Quasistatic nonconstraining torques (maximum 1.5 NM) induced flexion, extension, lateral bending (±1.5 NM), and axial rotation (±1.5 NM) on 32 sheep cervical spines (C2-C5). The motion segment C3-C4 was first tested intact; the following groups were tested after complete discectomy: autologous tricortical iliac crest bone graft, Medtronic-Wego polyetheretherketone (PEEK) cage, Solis PEEK cage, and BCFC. The autologous bone graft group was tested with an anterior plate. The mean range of motion (ROM) was calculated from the load-displacement curves. RESULTS BCFC significantly decreased ROM in lateral bending and axial rotation compared to other implants, and no significant difference in ROM between two types of PEEK cages and BCFC could be observed in flexion and extension. Anterior cervical plate (ACP) significantly decreased ROM in flexion and extension, but no significant difference in ROM between BCFC and bone graft plus ACP could be determined in lateral bending and axial rotation. CONCLUSION The BCFC device showed better stability to autologous tricortical iliac crest bone graft and PEEK cages in single-level anterior cervical discectomy and fusion models and thus may be a potential alternative to the current PEEK cages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study

STUDY DESIGN This is an experimental animal study. OBJECTIVE The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autologous bone graft and polyetheretherketone (PEEK) cages. BACKGROUND Although PLA cervical cages h...

متن کامل

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

Bioresorbable polylactide interbody implants in an ovine anterior cervical discectomy and fusion model: three-year results.

STUDY DESIGN In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model. OBJECTIVE To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process. SUMMARY OF BACKGROUND DATA The use of polylactide ...

متن کامل

Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage – clinical and radiological findings in an ovine animal model

BACKGROUND Bioabsorbable implants are not widely used in spine surgery. This study investigated the clinical and radiological findings after anterior cervical discectomy and fusion (ACDF) in an ovine animal model with an experimental bioabsorbable cage consisting of magnesium and polymer (poly-ϵ-caprolactone, PCL) in comparison to a tricortical bone graft as the gold standard procedure. MATER...

متن کامل

Biomechanical evaluation of stand-alone interbody fusion cages in the cervical spine.

STUDY DESIGN An in vitro biomechanical investigation of the immediate stability in cervical reconstruction. OBJECTIVES The purpose of this study was to compare the segmental stability afforded by the interbody fusion cage, the anterior locking plate, and the "gold standard" autograft. SUMMARY OF BACKGROUND DATA Recently, interbody fusion cage devices have been developed and used for cervica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012