Pulse Monitoring: Extending the Health-check for the Autonomic GRID

نویسنده

  • Roy Sterritt
چکیده

This paper upon looking at the Autonomic Computing architecture and Grid Computing highlights the importance of health check mechanisms to achieve a reflex-healing duel strategy. This will provide new design options for the development of the Autonomic Grid. The resulting pulse monitor is based on extending the existing Grid heart-beat monitor with urgency or anxiety levels such as that used in the NASA beacon monitor. The paper concludes with a discussion that this health check mechanism may be utilized in the future to achieve the necessary sense of urgency within a system for affect and emotion intelligence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A health-check model for autonomic systems based on a pulse monitor

Like the autonomic responses in the human body, autonomic computing systems recognise their own health problems and where possible respond to correct them. Failing that, external help is required. The purpose of this paper is to consider how autonomic systems might be structured to facilitate health monitoring. The approach uses a 'pulse' monitor for each autonomic element, which provides a ref...

متن کامل

Extending the Radar Dynamic Range using Adaptive Pulse Compression

The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...

متن کامل

آگاهی کارکنان درمانی بخش‌های ویژه نوزادان و کودکان درباره پالس‌اکسی‌متری

Background & Aim: Pulse Oximeter monitoring technology has become so common in intensive health care settings over the last decade that blood oxygen level is now considered as the fifth vital sign. However, it seems that medical and nursing staffs are not specially educated to operate with the devices. The aim of the study was to investigate the knowledge of medical assistants (residents), nurs...

متن کامل

A Component-based Architecture for an Autonomic Middleware Enabling Mobile Access to Grid Infrastructure

The increasing pervasiveness of wide-area distributed computing resources, like computational Grids, has given rise to applications that have inherent problems of complexity, adaptability, dynamism and heterogeneity etc. The emerging concept of autonomic computing holds the key to the selfmanagement of such a multifarious undertaking and provides a way to further build upon this complexity with...

متن کامل

Preliminary Design of Spacecraft Attitude Control with Pulse-Width Pulse-Frequency Modulator for Rest-to-Rest Maneuvers

In this paper, the preferred region of design parameters for quasi-normalized equations of single-axis attitude control of rigid spacecraft using pulse-width pulse-frequency modulator (PWPFM) is presented for rest-to-rest maneuvers. Using the quasi-normalized equations for attitude control reduces the system parameters, that is, the moment of inertia, the filter gain, and the maximum torque of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003