Electrical Design Considerations for a 40mhz Gas Ionization Chamber*

نویسندگان

  • P. Datte
  • P. F. Manfredi
چکیده

The front IR quadrupole absorbers (TAS) and the IR neutral particle absorbers (TAN) in the high luminosity insertions of the Large Hadron Collider (LHC) each absorb approximately 1.8 TeV of forward collision products on average per pp interaction (~235W at design luminosity 10cms). This secondary particle flux can be exploited to provide a useful storage ring operations tool for optimization of luminosity. A novel segmented, multi-gap, pressurized gas ionization chambers is being developed for sampling the energy deposited near the maxima of the hadronic/ electromagnetic showers in these absorbers. The ionization chamber must be capable of resolving individual bunch crossings at 40MHz. The ionization chamber is segmented into quadrants; each quadrant consists of sixty (40x40)mm Cu plates 1.0mm thick, with 0.5mm gaps. The 0.5mm gap width has been chosen so that the time for the ionization electrons to drift across the gap, is short enough to produce at the out put of the shaping amplifier, a signal that returns to the base line is less than the 25ns bunch spacing of the LHC. From noise considerations in the presence of a cable the stack of plates are connected electrically 10 in parallel, 6 in series to achieve an equivalent detector capacitance Cd~50pF. This type connection forms an electrode inductive Le and electrode capacitive Ce network that must be optimized to transfer charge from the chamber to the sensing amplifier. This paper describes the design of the collection electrodes optimized for 40 MHz operation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Design and fabrication of cylindrical ionization chamber for application in radiation protection

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

متن کامل

Design and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations

In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in...

متن کامل

Effective Design of a 3×4 Two Dimensional Distributed Amplifier Based on Gate Line Considerations

In this paper two dimensional wave propagation is used for power combining in drain nodes of a distributed amplifier (DA). The proposed two dimensional DA uses an electrical funnel to add the currents of drain nodes. The proposed structure is modified due to gate lines considerations. Total gain improvement is achieved by engineering the characteristic impedance of gate lines and also make appr...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001