Assessment of Myocardial Perfusion by Harmonic Power Doppler Imaging at Rest and During Adenosine Stress Comparison With Tc-Sestamibi SPECT Imaging
نویسندگان
چکیده
Background—Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by Tc-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress. Methods and Results—HPDI was performed on 123 patients who were referred for SPECT imaging for known or suspected coronary artery disease. Images were obtained at baseline and during adenosine infusion (0.14 mg z kg z min36 minutes) in 3 apical views. Myocardial perfusion by HPDI was graded for each coronary territory as absent, patchy, or full. The persistence of absent or patchy myocardial perfusion by HPDI between rest and adenosine was interpreted as a fixed defect, whereas any decrease in perfusion grade was interpreted as a reversible defect. Overall concordance between HPDI and SPECT was 83 (81%) of 103 for normal versus abnormal perfusion. Agreement between the 2 methods for each of the 3 coronary territories was 81% (k50.57) for the left anterior descending artery, 76% (k50.52) for the right coronary artery, and 72% (k50.40) for the left circumflex artery. Discrepancies between the 2 techniques were most notable in the circumflex territory, where fixed defects were observed in 33% by HPDI but in only 14% by SPECT (x515.8, P50.0001). Conclusions—This study demonstrates that HPDI can reliably detect myocardial perfusion during pharmacological stress, although there was a significantly higher number of falsely abnormal results in the circumflex territory. (Circulation. 2000;102:55-60.)
منابع مشابه
Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging.
BACKGROUND Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by (99m)Tc-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress. METHODS AND RESULTS HPDI was performed on 123 pat...
متن کاملAssessment of Myocardial Perfusion by Harmonic Power Doppler Imaging at Rest and During Adenosine Stress
Background—Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by Tc-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress. Methods and Results—HPDI was performed on 123 patients w...
متن کاملMyocardial contrast echocardiography yields best accuracy using quantitative analysis of digital data from pulse inversion technique: comparison with second harmonic imaging and harmonic power Doppler during simultaneous dipyridamole stress SPECT studies.
AIMS This prospective study assesses the (1) feasibility of quantifying ultrasound myocardial perfusion studies based on the densitometric analysis of digital data and the (2) comparison of pulse inversion, second harmonic and harmonic power Doppler modalities with SPECT. METHODS AND RESULTS Twenty-three patients with suspected ischaemic heart disease had i.v. injections of Tc-Sestamibi and O...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملThe role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000