A Note regarding Problems with Interaction and Varying Block Sizes in a Comparison of Endotracheal Tubes

نویسندگان

  • Richard L. Einsporn
  • Zhenyu Jia
چکیده

A randomized clinical experiment to compare two types of endotracheal tubes utilized a block design where each of the six participating anesthesiologists performed tube insertions for an equal number of patients for each type of tube. Five anesthesiologists intubated at least three patients with each tube type, but one anesthesiologist intubated only one patient per tube type. Overall, one type of tube outperformed the other on all three effectiveness measures. However, analysis of the data using an interaction model gave conflicting and misleading results, making the tube with the better performance appear to perform worse. This surprising result was caused by the undue influence of the data for the anesthesiologist who intubated only two patients. We therefore urge caution in interpreting results from interaction models with designs containing small blocks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparison of endotracheal intubation with nerve block and intravenous injection

Introduction: As endotracheal intubation is the first action which must be done for serious and very ill patients , so any procrastination leads to dangerous consequences including aspiration and finally death. Routine method for endotracheal intubation is injection of intravascular diazepam- Pethidine and sometimes muscle relaxants , but these drugs in Patients with GCS under 7 cause more decr...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Safe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review

Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...

متن کامل

بررسی عفونت بیمارستانی در NICU بیمارستان طالقانی، سالهای 1380 و 1381

Background : Nosocomial sepsis continues to be a significant cause of mortality in neonatal intensive care unit (NICU). Various interventional policies have been adopted to reduce its incidence. This study was designed to investigate the role of preventive strategies to bring down the incidence of nosocomial sepsis in the NICU. Materials and methods : The NICU was moved to a new location in 200...

متن کامل

Experimental Study of the Heat Transfer Enhancement in Concentric Tubes With Spherical and Pyramidal Protrusions

In the current research project, the thermal performance of a series of newly designed mixers has been investigated. Each mixer has two concentric cylinders comprising two annular slot flow channels around a solid cylindrical rod at the center. In each mixer, the first cylinder around the central solid rod has either spherical or pyramidal protrusions throughout the outer surface. It has been o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014