Optimization of Shaft Sleeve Slippage in High-Voltage Circuit Breaker Operation Mechanism

نویسندگان

  • Zhao Wenqiang
  • Zhang Haibo
  • Wu Shijing
  • Meng Fangang
چکیده

High-voltage circuit breakers are mechanical switching devices which connect and break current circuits (operating currents and fault currents) and carry the nominal current in closed position. As a result of multi-running, the shaft sleeve in operation mechanism could slip and even strip from the shaft at the hinge joint, which decreases the system reliability. In this work, investigations on the cause of sleeve slippage are proceeded, and the dimension parameters of shafting components where sleeve slippage occurs are optimized by incorporating a quasi-static mechanical model with Taguchi method. By developing and analyzing the mechanical model for the shaft sleeve slippage, it indicates that the sleeve slippage displacement has a same variation tendency with the shaft deflection. Theoretical equations are derived by using force analysis and superposition method to descript the analytic function of the shaft deflection. As the variables within the analytic function of the shaft deflection, the diameter and length of the shaft and the corresponding shaft sleeve length are selected as the control parameters in the optimization model. Moreover, several experiments are conducted by using the L18 (mixed orthogonal array) design method. Considering that the local mechanical characteristics such as sleeve strain are difficult to monitor via experimental method, an FEM simulation model is established to give the sleeve slippage displacement. Different levels of control parameters are introduced into the mechanical model and FEM simulation according to Taguchi method. The results from signal-to-noise (S/N) and ANOVA analysis (analysis of variance) reveal that shaft diameter is the most significant factor determining sleeve slippage in high-voltage circuit breaker operation mechanism, and that a larger diameter of shaft, a shorter shaft length and a longer sleeve length can reduce the sleeve slippage effectively. Meanwhile, the theoretical model is verified and enhanced by the FEM model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line Monitoring System based on Vibration Signal of High Voltage Circuit Breaker

High voltage circuit breaker is one of the most important switch apparatus in electrical power system. It play a role in the switch control, which can be used to switch the operating mode during normal operation (the equipment run or quit). In order to ensure the normal operation of the grid, it can be removed quickly when a malfunction on the device or circuit. Real-time online monitoring of h...

متن کامل

An Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices

Nowadays, high-voltage circuit breakers have reached such high short-circuit capabilities that testing them under the full rated voltage is generally not possible with direct tests, and they are conducted by using the synthetic test methods. Although the phenomena associated with making tests is of particular importance especially in case of load break switches, but making tests are rather d...

متن کامل

High-Voltage Circuit-Breaker Fault Diagnosis Based on Mechanical Vibration Signals

In order to guarantee the operation stability of high-voltage circuit-breaker, this paper extracts eigenvector of vibration signals based on mining of characteristic entropy of the wavelet packet obtained under the state of circuit breaker. Besides, the eigenvector of various fault samples is adopted as the input information of the BP network. After that, the author conducts training of the wel...

متن کامل

Analysis and Vibration Behavior of a Medium Voltage Spring Operated Switch Gear Mechanism used for Circuit Breaker

In recent years, considerable attention has been given to the analysis of flexible mechanisms. For mechanisms which operate at high speeds, the inertial forces become so large and they cannot be ignored and the mechanism members undergo considerable deformation. Under these situations the rigid body assumption is no longer valid and hence the need arises for consideration of the flexibilities o...

متن کامل

Investigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment

Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...