Instrument for precision long-term β-decay rate measurements.
نویسندگان
چکیده
We describe an experimental setup for making precision measurements of relative β-decay rates of (22)Na, (36)Cl, (54)Mn, (60)Co, (90)Sr, (133)Ba, (137)Cs, (152)Eu, and (154)Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.
منابع مشابه
A Novel Technique to Determine Atmospheric Ion Mobility Spectra
Detailed tropospheric ion measurements are needed to improve understanding of the electrical microphysics affecting clouds. Additionally, atmospheric ion mobility spectra can be used to identify ion growth processes leading to condensation nucleus formation. However these measurements are rare, particularly in the troposphere where the majority of clouds form. Developments in the operating theo...
متن کاملOrder α 2 corrections to the decay rate of orthopositronium
Order α 2 corrections to the decay rate of orthopositronium are calculated in the framework of nonrelativistic QED. The resulting contribution is found to be in significant disagreement with one set of experimental measurements, though another experiment is in agreement with theory. The discrepancy between theory and experiment for the decay rate of orthopositronium has long been one of the out...
متن کامل0 Order α 2 corrections to the decay rate of orthopositronium
Order α 2 corrections to the decay rate of orthopositronium are calculated in the framework of nonrelativistic QED. The resulting contribution is found to be in significant disagreement with one set of experimental measurements, though another experiment is in agreement with theory. The discrepancy between theory and experiment for the decay rate of orthopositronium has long been one of the out...
متن کاملNew Method for Isotopic Ratio Measurements of Atmospheric Carbon Dioxide Using a 4.3 μm Pulsed Quantum Cascade Laser
We present a new approach to the measurement of stable isotopic ratios of carbon dioxide using a near room temperature pulsed quantum cascade laser and a spectral ratio method based upon dual multiple pass absorption cells. The spectral ratio method improves precision and accuracy by reducing sensitivity to variations in the laser tuning rate, power and line width. The laser is scanned across t...
متن کاملFluorescence lifetime plate reader: resolution and precision meet high-throughput.
We describe a nanosecond time-resolved fluorescence spectrometer that acquires fluorescence decay waveforms from each well of a 384-well microplate in 3 min with signal-to-noise exceeding 400 using direct waveform recording. The instrument combines high-energy pulsed laser sources (5-10 kHz repetition rate) with a photomultiplier and high-speed digitizer (1 GHz) to record a fluorescence decay w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 86 7 شماره
صفحات -
تاریخ انتشار 2015