Mortalit Benefits and the Implantable Cardioverter - Defibrillator

نویسنده

  • Jeremy N. Ruskin
چکیده

The automatic implantable cardioverter-defibrillator (ICD) is highly effective in reducing sudden death rates in patients with life-threatening ventricular tachyarrhythmias. However, the magnitude of the ability of the ICD to improve overall survival is less certain. Data supporting the contention that the ICD prolongs survival are reviewed. It is evident that the mortality benefit consequent to the marked reduction in Tnhe automatic implantable cardioverter-defibrillator (ICD) was originally conceived by Mirowski and coworkers' as a device for detecting and terminating potentially lethal ventricular tachyarrhythmias. Since the initial published report of successful resuscitation from ventricular tachycardia and fibrillation in humans 13 years ago, more than 30 000 devices have been implanted, and there have been dramatic advances in ICD technology. Newer devices are fully programmable and capable of antitachycardia pacing, synchronized cardioversion, defibrillation, back-up ventricular demand pacing, and retrieval of stored intracardiac electrograms. There is universal agreement that the device has demonstrated the ability to meet the goal set forth by its inventors, namely, to abort sudden cardiac death caused by ventricular tachyarrhythmias. In highrisk patients who have survived cardiac arrest or have drug-refractory hemodynamically significant ventricular tachyarrhythmias, the ICD is highly effective in reducing sudden death rates, in most studies to 1% and 5% at 1 and 3 years, respectively.2-8 However, while acknowledging this dramatic reduction in sudden death rates, some reports suggest that treatment with the ICD is not paralleled by a proportionate reduction in overall mortality.2,9 Skeptics have seriously questioned the magnitude of the ability of the ICD to improve survival,10-12 giving rise to a controversy described as the implantable defibrillator "backlash."'13 They argue that regardless of the ability of the device to terminate potentially fatal ventricular tachyarrhythmias (which is not in question), it has not been convincingly shown to prolong life compared with alternate therapies, and the cost and morbidity of the technology remain unjustified. In this article, early studies with the ICD and the origins of the survival benefit controversy are reviewed. It is evident that the mortality benefit consequent to the marked reduction in sudden death varies widely across subpopulations in a predictable Received August 2, 1993; revision accepted December 9, 1993. From the Cardiac Arrhythmia Service, Massachusetts General Hospital, Harvard Medical School, Boston. Correspondence to Dr Ruskin, Cardiac Arrhythmia Service, Massachusetts General Hospital, Boston, MA 02114. sudden death varies widely across subpopulations in a predictable manner. This observation reflects the powerful influence of other clinical factors that constrain survival in typical ICD patients. The implications for future studies on the ICD are discussed. (Circulation. 1994;89:1851-1858.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

تأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)

  Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients .   Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005