ABSTRACT TEMPLATE FOR ASim 2012

نویسندگان

  • Liping Wang
  • Tianzhen Hong
چکیده

Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying * Corresponding author email: [email protected] EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ABSTRACT TEMPLATE FOR ASim 2012

In this paper, parametric design approach is used to optimize the external shading device design, which take examples of horizontal shading devices and horizontal louver shading devices on south faced of buildings in Guangzhou, Shanghai and Beijing. The optimize goal of whole year shading effect is “Shading in summer and solar in winter, both as much as possible at the same time”. In the first ...

متن کامل

ABSTRACT TEMPLATE FOR ASim 2012

In addition to the MPC(Model Predictive Control) study in estimating in advance the control applicable to actual buildings based on a model in which a simulation tool is used, a variety of studies, including temperature control, lighting control, and operation strategy, have been conducted recently. Actual buildings are controlled and operated in the integrative mode, and, therefore, the impact...

متن کامل

Abstract Template

s 2012 "Procedurally
generating
everything" Micah
Caunter
(Computer
Science) Advised
by
Denise
Byrnes
(CS)


متن کامل

Proving Termination by Policy Iteration

In this paper, we explore the adaptation of policy iteration techniques to compute greatest fixpoint approximations, in order to find sufficient conditions for program termination. Restricting ourselves to affine programs and the abstract domain of template constraint matrices, we show that the abstract greatest fixpoint can be computed exactly using linear programming, and that strategies are ...

متن کامل

The synthesis of some new hydrazone derivatives containing the benzothiazole moiety

Abstract: Hydrazones are an important class of compounds found in many synthetic products. Due to their importance in synthetic chemistry, the present article reports the synthesis of a new series of ten compounds based on the coupling of 2-oxo-3(2H)-benzothiazoleacetic acid, hydrazide and 2-thioxo-3(2H)-benzothiazoleacetic acid, hydrazide with different aldehydes. The structures of the synthes...

متن کامل

Effects of Drip Irrigation, Embedded System and Fertilizers on Sugarcane

[1] Mr. S.G. Galande, [2] Dr. G. H. Agrawal [1] Ph.D. Scholar, RTM Nagpur University, Nagpur, INDIA e-mail:[email protected], Mobile no: 9423466197 [2] Professor, KDK Engineering College, Nadanvan, Nagpur, INDIA Email ID: [email protected], mobile no: +918446985231 __________________________________________________________________________________________ Abstract: An abstract summarizes, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012