Perioperative sequential monitoring of hemodynamic parameters in patients with pheochromocytoma using the Non-Invasive Cardiac System (NICaS).

نویسندگان

  • Yayoi Matsuda
  • Hisaya Kawate
  • Shingo Shimada
  • Chitose Matsuzaki
  • Hiromi Nagata
  • Masahiro Adachi
  • Keizo Ohnaka
  • Masatoshi Nomura
  • Ryoichi Takayanagi
چکیده

Surgical treatment of pheochromocytoma is associated with a high risk of hemodynamic instability. To reduce the risk of perioperative complications, adequate medical treatment to normalize blood pressure and restore blood volume is required. Accurate evaluation of the circulating blood volume (CBV) in perioperative patients with pheochromocytoma is clinically important. In the present study, we adopted whole-body bioimpedance monitoring technique using the Non-Invasive Cardiac System (NICaS), which can non-invasively measure cardiac output (CO) values. NICaS-derived CO values were evaluated in eight preoperative patients with pheochromocytoma and were compared with simultaneous CBV values measured by a conventional indicator dilution method using (131)I-labeled human serum albumin. In these patients with pheochromocytoma, the NICaS-derived CO values were significantly correlated with the CBV values measured by (131)I-labeled human serum albumin (4.86 ± 1.05 L/min vs 4.79 ± 1.02 L; r = 0.906; P = 0.002). Sequential NICaS-derived CO values confirmed that CBV increased after preoperative treatment with an α-blocker, with or without volume loading. The results of this study indicate that NICaS can be used to accurately and non-invasively evaluate the hemodynamic status. By sequential monitoring of NICaS-derived CO values, we are able to confirm whether adequate CBV in a patient with pheochromocytoma is obtained by preoperative medical treatment with α-blockers or volume loading, to avoid perioperative complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole body bioimpedance monitoring for outpatient chronic heart failure follow up.

BACKGROUND Although cardiac output index (CI), stroke volume index (SVI), and total systemic vascular resistance (TSVR) are important hemodynamic parameters for the prognosis of chronic heart failure (CHF), they are difficult to measure in an outpatient setting. Whole body bioimpedance monitoring using a Non-Invasive Cardiac System (NICaS) allows for easy, non-invasive estimation of these param...

متن کامل

مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری

Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Evaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring

Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...

متن کامل

Noninvasive and simple assessment of cardiac output and pulmonary vascular resistance with whole-body impedance cardiography is useful for monitoring patients with pulmonary hypertension.

BACKGROUND Right heart catheterization (RHC) is the gold standard for the diagnosis of pulmonary hypertension (PH) and a useful tool for monitoring PH. However, there are some disadvantages in the regular use of RHC because it is invasive. Noninvasive methods for monitoring hemodynamics are needed to manage patients with PH. In this study, we aimed to evaluate the reliability of noninvasive hem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endocrine journal

دوره 61 6  شماره 

صفحات  -

تاریخ انتشار 2014