Central corneal thickness and intraocular pressure relationship in eyes with and without previous lasik - Comparison of Goldmann applanation tonometer with pneumatonometer.
نویسندگان
چکیده
PURPOSE To investigate central corneal thickness (CCT) and intraocular pressure (IOP) relationship in eyes with and without previous corneal laser refractive surgery and to compare the estimates of two different tonometersGoldmann applanation and pneumatonometer. METHODS The study population included 234 glaucoma suspects who were referred to the glaucoma clinic with cup/disc ratios greater than 0.4, asymmetric cupping, and/or IOP greater than 22 mmHg during routine eye examination. Of those, 84 had previous myopic laser-assisted in situ keratomileusis (LASIK) (Group 1) while 150 of them did not (Group 2). CCT was measured by using optical coherence tomography (OCT) and IOP with both Goldmann applanation tonometer (GAT) and pneumatonometer (PT). In both groups, the difference between IOP estimates of two different tonometers and the relationship between CCT and IOP were analyzed. RESULTS In eyes with previous LASIK, GAT measured IOP significantly lower than PT (mean difference of 3.81.9 mmHg, p<0.0001). In eyes with virgin corneas, IOP estimates of GAT or PT were not different from each other (19.92.8 versus 19.92.2 mmHg, respectively, p=0.81). In both groups, there was a significant positive correlation between CCT and IOP estimates of GAT (R=0.29, p=0.007 in eyes with LASIK and R=0.38, p<0.0001 in those without), while no similar relationship was present between CCT with those of PT (R=0.03, p=0.76 in eyes with LASIK and R=0.03, p=0.69 in those without). CONCLUSIONS In eyes with previous LASIK, GAT measured IOP significantly lower than PT. Because IOP estimates of PT were found to be independent from CCT in all of the study eyes, this device was considered to be a more reliable method of IOP estimation than GAT in eyes with and without previous LASIK. (Eur J Ophthalmol 2005; 15: 81-8).
منابع مشابه
Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.
AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...
متن کاملIntraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.
The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملGoldmann tonometer error correcting prism: clinical evaluation
PURPOSE Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. METHODS A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness,...
متن کاملIntraocular pressure and ocular rigidity after LASIK.
PURPOSE To assess the intraocular pressure (IOP) and ocular rigidity (E) at 1, 3, 6 and 24 postoperative months in eyes that underwent LASIK. METHODS The IOP measured by Goldmann applanation tonometer (GAT) and by the 5.5 and 10 gm. weights of a standardized Schioetz tonometer (ST) and the E measured by differential tonometry (the 5.5 and 10 gm. of ST) were assessed before and after LASIK (at...