Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis.
نویسندگان
چکیده
BACKGROUND AND PURPOSE I.v. FDCT angiography is an emerging technology for the detection of intracranial vascular disease. This study was conducted to determine the feasibility of i.v. FDCT in estimating major atherosclerotic intracranial arterial stenosis with DSA as the reference. MATERIALS AND METHODS DSA and i.v. FDCT were performed simultaneously in patients with transient ischemic attack or acute cerebral infarction. The degree and length of stenosis were measured. The stenotic vessels were categorized into 4 groups by the grade of stenosis: normal (<30%), mild (30%-49%), moderate (50%-69%), or severe (>70%). The vessels of the normal group were excluded from analysis to reduce spectrum bias. Measurement of vessels was recorded by using an electric ruler by a qualified endovascular neurosurgeon and a neuroradiologist. RESULTS Eight hundred forty-two vessel segments in 69 patients were calculated. Mild (n = 56), moderate (n = 47) and severe stenosis (n = 46) groups were analyzed. I.v. FDCT had a sensitivity of 97.6%, specificity of 96.9%, and negative predictive value of 96.9% for detecting ≥50% stenosis and respective values of 91.9%, 98.2%, and 97.4% for depicting ≥70% stenosis. The difference of stenotic length between the 2 tests was not significant as an increase in the severity of stenosis (Spearman rank correlation test; r = -0.12, P = .13). CONCLUSIONS I.v. FDCT can be a feasible alternative as a noninvasive method for evaluating stenosis of the major intracranial arteries.
منابع مشابه
Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment
BACKGROUND Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. OBJECTIVE To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image ...
متن کاملFlat detector angio-CT following intra-arterial therapy of acute ischemic stroke: identification of hemorrhage and distinction from contrast accumulation due to blood-brain barrier disruption.
BACKGROUND AND PURPOSE Flat panel detector CT in the angiography suite may be valuable for the detection of intracranial hematomas; however, abnormal contrast enhancement frequently mimics hemorrhage. We aimed to assess the accuracy of flat panel detector CT in detecting/excluding intracranial bleeding after endovascular stroke therapy and whether it was able to reliably differentiate hemorrhag...
متن کاملAngiographic CT in cerebrovascular stenting.
We evaluated the feasibility of angiographic CT (ACT) for visualizing metallic stents in three patients who underwent intracranial (n = 2) or extracranial (n = 1) stent placement to treat atherosclerotic lesions. ACT is a new technique that provides cross-sectional CT-like images based on rotational radiography performed with a rotating C-arm-mounted flat-panel detector. ACT allowed for the cle...
متن کاملIntravenous C-Arm Conebeam CT Angiography following Long-Term Flow-Diverter Implantation: Technologic Evaluation and Preliminary Results.
BACKGROUND AND PURPOSE A noninvasive investigation with high spatial resolution and without metal artifacts is necessary for long-term imaging follow-up after flow-diverter implantation. We aimed to evaluate the diagnostic value of conebeam CT angiography with intravenous contrast enhancement in the assessment of vascular status following implantation of the Pipeline Embolization Device and to ...
متن کاملUtilizing flat-panel detector parenchymal blood volume imaging (FD-PBV) for quantitative kidney perfusion analysis during the process of percutaneous transluminal renal angioplasty (PTRA)
Rationale: Traditional digital subtraction angiography (DSA) provides lumen morphology of renal artery as indicators for vascular patency in patients with renal artery stenosis (RAS). It, however, lacks hemodynamic information toward target kidney. To solve this shortcoming, a novel technique, flat-panel detector parenchymal blood volume imaging (FD-PBV), is introduced, which is able to evaluat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 34 1 شماره
صفحات -
تاریخ انتشار 2013