Echo-time independent signal modulations for strongly coupled systems in triple echo localization schemes: an extension of S-PRESS editing.

نویسندگان

  • Nils Kickler
  • Giulio Gambarota
  • Ralf Mekle
  • Rolf Gruetter
  • Robert Mulkern
چکیده

The double spin-echo point resolved spectroscopy sequence (PRESS) is a widely used method and standard in clinical MR spectroscopy. Existence of important J-modulations at constant echo times, depending on the temporal delays between the rf-pulses, have been demonstrated recently for strongly coupled spin systems and were exploited for difference editing, removing singlets from the spectrum (strong-coupling PRESS, S-PRESS). A drawback of this method for in vivo applications is that large signal modulations needed for difference editing occur only at relatively long echo times. In this work we demonstrate that, by simply adding a third refocusing pulse (3S-PRESS), difference editing becomes possible at substantially shorter echo times while, as applied to citrate, more favorable lineshapes can be obtained. For the example of an AB system an analytical description of the MR signal, obtained with this triple refocusing sequence (3S-PRESS), is provided.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

Single Echo Time Glutamate Editing at 3 Tesla

Introduction Glutamate plays an important role in normal brain function and in brain disorders. Recently, MRS measurement of total glutamate concentration has been applied to studying several neurological and psychiatric disorders. Short-TE single voxel MRS methods cannot separate glutamate from overlapping resonances at field strengths accessible to most clinical studies. As a result, spectral...

متن کامل

PRESS Difference Spectroscopy Optimization Applied to GABA and Tau at 3 T

Introduction Detection of γ−aminobutyric acid (GABA), an important inhibitory neurotransmitter, at 3 T via Magnetic Resonance Spectroscopy (MRS) generally requires a spectral editing technique as the peaks of the GABA signal are obscured by overlapping metabolite resonances including glutamate (Glu), glutamine, creatine (Cr) and Nacetylaspartate (NAA). Several spectral editing techniques have b...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

Measurement of Glycine in Human Brain by PRESS at 7.0 Tesla In Vivo

INTRODUCTION Glycine (Gly), an inhibitory neurotransmitter and co-agonist at N-methyl-D-aspartate receptors, has a singlet resonance at 3.55 ppm. Because of its low concentration and overlapping resonances of primarily myo-inositol (mI), detection of a small Gly signal by H-MRS is a challenge. A PRESS (point-resolved spectroscopy) TEaveraging method was employed to measure Gly at 4T [1]. Improv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 203 1  شماره 

صفحات  -

تاریخ انتشار 2010