Automatic Lumen Detection on Longitudinal Ultrasound B-Mode Images of the Carotid Using Phase Symmetry
نویسندگان
چکیده
This article describes a method that improves the performance of previous approaches for the automatic detection of the common carotid artery (CCA) lumen centerline on longitudinal B-mode ultrasound images. We propose to detect several lumen centerline candidates using local symmetry analysis based on local phase information of dark structures at an appropriate scale. These candidates are analyzed with selection mechanisms that use symmetry, contrast or intensity features in combination with position-based heuristics. Several experimental results are provided to evaluate the robustness and performance of the proposed method in comparison with previous approaches. These results lead to the conclusion that our proposal is robust to noise, lumen artifacts, contrast variations and that is able to deal with the presence of CCA-like structures, significantly improving the performance of our previous approach, from 87.5% ± 0.7% of correct detections to 98.3% ± 0.3% in a set of 200 images.
منابع مشابه
Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملAutomatic Segmentation of the Lumen of the Carotid Artery in Ultrasound B-mode Images Using Fuzzy Logic Classifier
In this paper, the new method is proposed for recognizing B-mode ultrasound (US) imaging of common carotid artery (CCA) in longitude. Automatic segmentation of the arterial lumen from ultrasound images is an important task in clinical diagnosis. Carotid artery recognition, the first task in lumen segmentation, should be performed in a fully automated, fast, and reliable way to further facilitat...
متن کاملExtraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm
Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...
متن کاملA novel automatic algorithm for the segmentation of the lumen of the carotid artery in ultrasound B - mode
A novel algorithm is proposed for the segmentation of the lumen and bifurcation boundaries of the carotid artery in B-mode ultrasound images. It uses the image contrast characteristics of the lumen and bifurcation of the carotid artery in relation to other tissues and structures for their identification. The relevant ultrasound data regarding the artery presented in the input image is identifie...
متن کاملDetection of the carotid artery lumen and bifurcation contours in ultrasound B-mode images
A new algorithm is proposed for the correct identification of the lumen and bifurcation contours of the carotid artery in ultrasound B-mode images. The algorithm uses hipoechogenic characteristics to guide the lumen identification and echogenic characteristics to detect the artery bifurcation. The input image is preprocessed for speckle removal by an anisotropic diffusion filter and morphologic...