Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from X-ray CT imaging.

نویسندگان

  • Osama I Saba
  • Eric A Hoffman
  • Joseph M Reinhardt
چکیده

To objectively quantify airway geometry from three-dimensional computed tomographic (CT) images, an idealized (circular cross section) airway model is parameterized by airway luminal caliber, wall thickness, and tilt angle. Using a two-dimensional CT slice, an initial guess for the airway center, and the full-width-half-maximum principle, we form an estimate of inner and outer airway wall locations. We then fit ellipses to the inner and outer airway walls via a direct least squares fit and use the major and minor axes of the ellipses to estimate the tilt and in-plane rotation angles. Convolving the airway model, initialized with these estimates, with the three-dimensional scanner point-spread function forms the predicted image. The difference between predicted and actual images is minimized by refining the model parameter estimates via a multidimensional, unconstrained, nonlinear minimization routine. When optimization converges, airway model parameters estimate the airway inner and outer radii and tilt angle. Results using a Plexiglas phantom show that tilt angle is estimated to within +/-4 degrees and both inner and outer radii to within one-half pixel when a "standard" CT reconstruction kernel is used. By opening up the ability to measure airways that are not oriented perpendicular to the scanning plane, this method allows evaluation of a greater sampling of airways in a two-dimensional CT slice than previously possible. In addition, by combining the tilt-angle compensation with the deconvolution method, we provide significant improvement over the previous full-width-half-maximum method for assessing location of the luminal edge but not the outer edge of the airway wall.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Boundary-Specific Cost Functions for Quantitative Airway Analysis

Computed tomography (CT) images of the lungs provide high resolution views of the airways. Quantitative measurements such as lumen diameter and wall thickness help diagnose and localize airway diseases, assist in surgical planning, and determine progress of treatment. Automated quantitative analysis of such images is needed due to the number of airways per patient. We present an approach involv...

متن کامل

Active contour approach for accurate quantitative airway analysis

Chronic airway disease causes structural changes in the lungs including peribronchial thickening and airway dilatation. Multi-detector computed tomography (CT) yields detailed near-isotropic images of the lungs, and thus the potential to obtain quantitative measurements of lumen diameter and airway wall thickness. Such measurements would allow standardized assessment, and physicians to diagnose...

متن کامل

In Vivo Computed Tomography as a Research Tool to Investigate Asthma and COPD: Where Do We Stand?

Computed tomography (CT) is a clinical tool widely used to assess and followup asthma and chonic obstructive pulmonary disease (COPD) in humans. Strong efforts have been made the last decade to improve this technique as a quantitative research tool. Using semiautomatic softwares, quantification of airway wall thickness, lumen area, and bronchial wall density are available from large to intermed...

متن کامل

Computed tomographic estimation of lung dimensions throughout the growth period.

The aim of the current study was to use computed tomography (CT) to estimate airway wall and lumen, and arterial and parenchyma dimensions in children throughout the growth period, and to provide normative data to study alterations caused by pulmonary disease. Clinical CT scans reported as normal that were performed in children for nonpulmonary and noncardiac reasons were analysed for lung weig...

متن کامل

Understanding the contribution of native tracheobronchial structure to lung function: CT assessment of airway morphology in never smokers

BACKGROUND Computed tomographic (CT) airway lumen narrowing is associated with lower lung function. Although volumetric CT measures of airways (wall volume [WV] and lumen volume [LV]) compared to cross sectional measures can more accurately reflect bronchial morphology, data of their use in never smokers is scarce. We hypothesize that native tracheobronchial tree morphology as assessed by volum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 95 3  شماره 

صفحات  -

تاریخ انتشار 2003