Evaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.

نویسندگان

  • Refat Jabara
  • Nicolas Chronos
  • Damian Conway
  • Warner Molema
  • Keith Robinson
چکیده

OBJECTIVES We sought to evaluate a new second-generation drug-eluting stent (DES), comprising a slow-release biodegradable polylactide coglycolide (PLGA) polymer and low-dose paclitaxel on a thin-strut cobalt chromium stent platform, in a clinically relevant animal model. BACKGROUND Our previous work demonstrated subacute vascular toxicity and necrosis triggering late excess neointima in pig coronaries, with a moderate paclitaxel dose eluted from an erodible polymer. The use of slower-releasing absorbable polymers with lower doses of paclitaxel is expected to minimize such adverse outcomes. METHODS Three types of stents were implanted in pig coronary arteries using quantitative coronary angiography to optimize stent apposition: bare-metal stents (BMS); absorbable, slow-release polymer-coated-only stents (POLY); and absorbable polymer-based paclitaxel-eluting stents (PACL). The dose density of paclitaxel was 0.15 microg/mm(2) with in vitro studies demonstrating a gradual elution over the course of 12 to 16 weeks. Animals underwent angiographic restudy and were terminated at 1 and 3 months for complete histopathologic and histomorphometric analyses. RESULTS At 1 month, intimal thickness varied significantly according to stent type, with the lowest level for the PACL group compared with the BMS and POLY groups (0.06 +/- 0.02 mm vs. 0.17 +/- 0.07 mm, 0.17 +/- 0.08 mm, respectively, p < 0.001); histological percent area stenosis was 18 +/- 4% for PACL compared with 27 +/- 7% for BMS and 30 +/- 12% for POLY, respectively (p = 0.001). At 3 months, PACL showed similar neointimal thickness as BMS and POLY (0.09 +/- 0.05 mm vs. 0.13 +/- 0.10 mm and 0.11 +/- 0.03 mm respectively, p = 0.582). Histological percent area stenosis was 23 +/- 8% for PACL versus 23 +/- 11% for BMS and 23 +/- 2% for POLY, respectively (p = 1.000). CONCLUSIONS This study shows favorable vascular compatibility and efficacy for a novel DES that elutes paclitaxel in porcine coronary arteries. These results support the notion that slowing the release rate and lowering the dose of paclitaxel favorably influences the vascular biological response to DES implant, decreasing early toxicity and promoting stable healing while still suppressing neointima formation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized trial of rapamycin- and paclitaxel-eluting stents with identical biodegradable polymeric coating and design.

AIMS This prospective, randomized study sought to directly compare the performance of paclitaxel and rapamycin on an otherwise identical, polymer-coated drug-eluting stent (DES) platform. METHODS AND RESULTS Stents with identical design and biodegradable polymeric coating that elute either rapamycin or paclitaxel over a 2 months time period were utilized. In this pilot trial that included 91 ...

متن کامل

Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating.

OBJECTIVE The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. METHODS AND RESULTS The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating ...

متن کامل

Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial

BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro ...

متن کامل

The effect of variable dose and release kinetics on neointimal hyperplasia using a novel paclitaxel-eluting stent platform: the Paclitaxel In-Stent Controlled Elution Study (PISCES).

OBJECTIVES The aim of this study was to evaluate the effect of variable dose and release kinetics of paclitaxel on neointimal hyperplasia. BACKGROUND Conventional paclitaxel-eluting stents use a durable polymer coating as a vehicle for drug delivery. The Conor stent (Conor Medsystems, Menlo Park, California) with intra-strut wells and erodable polymer is specifically designed for drug deliver...

متن کامل

Safety and efficacy of a non-polymeric paclitaxel-eluting microporous stent in real-world percutaneous coronary intervention

At present, there is an increasing focus on stents that have a biodegradable polymer coating, rather than a permanent polymer coating. This is due to the fact that following the implantation of a drug-eluting stent (DES) with a permanent polymer coating, the continued existence of the coating may result in a foreign body reaction and delayed re-endothelialization. The aim of the present study w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2008