[Method of measuring modulation transfer function using metal wire in computed tomography].
نویسندگان
چکیده
The current scanning parameters for computed tomography (CT) such as multi-detector row CT are becoming more complicated, and there are many cases in which the selected parameters directly affect image quality. Therefore, to evaluate the effectiveness and validity of the selected parameter, quantitative image quality evaluations are indispensable. Among the items of evaluation, modulation transfer function (MTF) is one of the most important in evaluating the resolution property. Several guidelines for performance evaluation for CT have been reported since the era of early CT diffusion. In those guidelines, it is recommended that the resolution property needs to be measured by the wire method, in which a phantom designed to support a thin metal wire along an axis perpendicular to the slice plane is used. However, the academic papers describing the wire method are so old that the detailed methodology corresponding to currently available CT specifications cannot be conducted. However, the fundamental principles are still effective. In this study, we examined the calculation method, phantom design and allocation, wire material, and other factors suitable for current CT specifications, and derived some recommendations from them.
منابع مشابه
Evaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملMTF Measurement Based on Interactive Live-Wire Edge Extraction
When we want to measure parameters of the Modulation Transfer Function (MTF) from remote sensing image directly, the sharp edges are usually used as targets. But for noise, blur and the complexity of the images, fully automatic locating the expected edge is still an unsolved problem. This paper improves the semi-auto edge extraction algorithm of live-wire [1] and introduces it into the knife-ed...
متن کاملAccurate determination of CT point‐spread‐function with high precision
The measurement of modulation transfer functions (MTFs) in computed tomography (CT) is often performed by scanning a point source phantom such as a thin wire or a microbead. In these methods the region of interest (ROI) is generally placed on the scanned image to crop the point source response. The aim of the present study was to examine the effect of ROI size on MTF measurement, and to optimiz...
متن کاملDesign and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملPredicting Unilateral Postlaminectomy C5 Palsy by Measuring C5 Exit Foramen Area on Preoperative Computed Tomography
Background. Postoperative C5 motor palsy is known as a common complication not only after cervical laminectomy but also after anterior discectomy. There is no consensus to verify any of the proposed mechanisms of C5 palsy following posterior cervical decompression. The authors of this article have found that C5 palsy is more common among patients with smaller C5 root exit foramen area. The purp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 64 6 شماره
صفحات -
تاریخ انتشار 2008