Stabilized lipid film based biosensor for atenolol.

نویسندگان

  • Dimitrios P Nikolelis
  • Maria Mitrokotsa
چکیده

This work reports a technique for the stabilization after storage in air of a lipid film based biosensor for atenolol. Microporous filters composed of glass fibers (nominal pore sizes 0.7 and 1.0 microm) were used as supports for the formation and stabilization of these devices. The lipid film is formed on the filter by polymerization prior to its use. Methacrylic acid was the functional monomer, ethylene glycol dimethacrylate was the crosslinker and 2,2'-azobis-(2-methylpropionitrile) was the initiator. The method for preparation of stabilized lipid film biosensor is studied throughout this work. The response towards atenolol of these stabilized lipid membrane biosensor, for repetitive use, composed of phosphatidylcholine was compared with planar freely suspended bilayer lipid membranes (BLMs). The stabilized lipid membranes provided similar artificial ion gating events as BLMs in the form of transient signals and can function for repetitive uses after storage in air. This will allow the practical use of the techniques for chemical sensing based on lipid films and commercialization of these devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of HLB on the Release Profile of Atenolol from Ethyl Cellulose-coated Tablets

It is possible to alter the permeability of ethyl cellulose membrane with certain materials such as surfactants. In this study the effect of surfactant concentration and different HLB values on the release rate of atenolol from ethyl cellulose-coated tablets was evaluated. The results showed that when the concentration of surfactant increased, the rate of drug release also increased. The kineti...

متن کامل

The Effect of HLB on the Release Profile of Atenolol from Ethyl Cellulose-coated Tablets

It is possible to alter the permeability of ethyl cellulose membrane with certain materials such as surfactants. In this study the effect of surfactant concentration and different HLB values on the release rate of atenolol from ethyl cellulose-coated tablets was evaluated. The results showed that when the concentration of surfactant increased, the rate of drug release also increased. The kineti...

متن کامل

Modified Glass Carbon Electrode (GCE) Electropolymerized Polypyrrole Nanofibers with Hemoglobin (Hb) Film as a Unique Biosensor for Nitrite Determination

Abstract: In this study, we were investigated behavior the electrochemical reductionof nitrite at a hemoglobin (Hb) immobilized on glass carbon electrode (GCE) containingpolypyrol nanofiber (ppy) films. Polypyrrole (PPy) nanofibers have been constructed onGCE applying electrochemical technique, and can to deposit diverse polymers onminiaturized electrodes with this commo...

متن کامل

Protein-Based Graphene Biosensors: Optimizing Artificial Chemoreception in Bilayer Lipid Membranes

Proteinaceous moieties are critical elements in most detection systems, including biosensing platforms. Their potential is undoubtedly vast, yet many issues regarding their full exploitation remain unsolved. On the other hand, the biosensor formats with the higher marketability probabilities are enzyme in nature and electrochemical in concept. To no surprise, alternative materials for hosting c...

متن کامل

A Simple Visual Ethanol Biosensor Based on Alcohol Oxidase Immobilized onto Polyaniline Film for Halal Verification of Fermented Beverage Samples

A simple visual ethanol biosensor based on alcohol oxidase (AOX) immobilised onto polyaniline (PANI) film for halal verification of fermented beverage samples is described. This biosensor responds to ethanol via a colour change from green to blue, due to the enzymatic reaction of ethanol that produces acetaldehyde and hydrogen peroxide, when the latter oxidizes the PANI film. The procedure to o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 17 6-7  شماره 

صفحات  -

تاریخ انتشار 2002