I Beam Transport Radiation Shielding for Branch Lines

نویسندگان

  • Y. P. Feng
  • B. Lai
چکیده

The x-ray radiation shielding requirements beyond the first optics enclosure have been considered for the beam transport of the 2-ID-B and 2-ID-C branch lines of Sector 2 (SRI-CAT) of the APS. The first three optical components (mirrors) of the 2-ID-B branch are contained within the shielded first optics enclosure. Calculations indicate that scattering of the primary synchrotron beam by beamline components outside the enclosure, such as apertures and monochromators, or by gas particles in case of vacuum failure is within safe limits for this branch. A standard 2.5-inch-diameter stainless steel pipe with 1I16-inch-thick walls provides adequate shielding to reduce the radiation dose equivalent rate to human tissue to below the maximum permissible limit of 0.25 mremlhr. The 2-ID-C branch requires, between the first optics enclosure where only two mirrors-are used and the housing for the third mirror, additional lead shielding (0.75 mm) and a minimum approach distance of 2.6 cm. A direct beam stop consisting of at least 4.5 mm of lead is also required immediately downstream of the third mirror for 2-ID-C. Finally, to stop the direct beam from escaping the experimental station, a beam stop consisting of at least 4-mm or 2.5-mm steel is required for the 2-ID-B or 2-ID-C branches, respectively. This final requirement can be met by the vacuum chambers used to house the experiments for both branch lines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Calculations for Advanced Proton Therapy Facility

The shielding calculations of bulk shielding for Advanced Proton Therapy Facility (APTRON) which is under design in Shanghai were carried out. The thickness of radiation shielding walls for the accelerator and treatment rooms of APTRON were determined by Monte Carlo simulation and empirical methods [1~3]. Assumptions of beam loss scenarios and workloads of different energy at LINAC, synchrotron...

متن کامل

Impact of Gas Bremsstrahlung on Synchrotron Radiation Beamline Shielding at the Advanced Photon Source+

The Advanced Photon Source (APS) currently under construction at Argonne National Laboratory will be one of the world’s brightest synchrotron radiation facilities. The storage ring, capable of storing currents up to 300 mA at 7.0 GeV and 200 mA at 7.5 GeV, will produce very intense and energetic synchrotron radiation (Ec = 24 keV for bending magnets and Ec = 37.4 keV for wigglers, where Ec is t...

متن کامل

Secondary Particles Produced by Hadron Therapy

Introduction Use of hadron therapy as an advanced radiotherapy technique is increasing. In this method, secondary particles are produced through primary beam interactions with the beam-transport system and the patient’s body. In this study, Monte Carlo simulations were employed to determine the dose of produced secondary particles, particularly neutrons during treatment. Materials and Methods I...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

Radiation Protection Study for the Shielding Design of the Linac4 Beam Dump at Cern

The aim of this study is to determine an optimal shielding of the LINAC4 beam dump fulfilling the radiation protection requirements. Therefore a detailed Monte-Carlo calculation using FLUKA particle transport and interaction code has been performed and the relevant physics quantities, such as particle fluences, neutron energy spectra, residual and prompt dose rates, air and water activation hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995