Magnetic Resonance Imaging for the Assessment of Gastro-Esophageal Junction

نویسندگان

  • J. Curcic
  • R. Treier
  • E. Kaufman
  • Z. Forras-Kaufman
  • M. Fox
  • W. Schwizer
  • M. Fried
  • P. Boesiger
چکیده

Introduction: Gastro-esophageal reflux disease (GERD) is present when repeated backflow of gastric contents into the esophagus causes chronic symptoms or damages the esophageal lining. In recent years, the prevalence of GERD has increased and there is a strong correlation between acid reflux and the increasing incidence of esophageal cancer [1]. The gastro-esophageal junction (GEJ) is the key defense against acid reflux. Its most important structural components are the lower esophageal sphincter (LES), the crural diaphragm and the insertion angle of the esophagus into the stomach acting as a flap valve mechanism (Figure 1). Early developments in manometry measurements revealed that most reflux events occur during transient lower esophageal sphincter relaxations (TLESRs) [2]. More recently it was found that the frequency and duration of the TLESRs in GERD patients and healthy volunteers is similar, however in GERD patients TLESRs are more likely to be associated with acid reflux while in health they are associated with gas or liquid without acid [3]. These findings indicate that although most reflux events occur during functional relaxations of the GEJ it is the structure of this area that increases the frequency of the reflux events. The aim of this study is to non-invasively assess structure and function of the GEJ in healthy volunteers and GERD patients using magnetic resonance imaging. Methods: Magnetic resonance imaging (MRI) combined with high-resolution manometry (HRM) as reference technique was applied to analyze the structure and function of the GEJ. MRI measurements were performed using 1.5T whole-body MRI system (Philips Healthcare, Best, NL) and HRM measurements using water-perfused HRM system (Advanced Manometry Systems, Melbourne, AUS). 12 healthy volunteers (5 women) and 6 GERD patients (3 women) were examined before and after ingestion of a high-caloric solid/liquid meal. Solid meal: cheeseburger with French fries; liquid meal: chocolate-milkshake. Anatomic and dynamic scans were performed alternately every 30 minutes over 2 hours to assess the structure of the GEJ and to detect reflux events, respectively. Scan parameters: anatomic scan: 30 transverse slices, bFFE sequence, FOV=360x285mm, scan matrix=192x190, slice thickness=4mm, scan time=15s (breath hold); dynamic scan: 3 oblique coronal slices, 3x380 dynamics, 330ms/dynamic, bFFE sequence, FOV=360x285mm, scan matrix=192x190, slice thickness=8mm, SENSE factor=1.6. Stomach and esophagus were contoured semi-automatically on every image of the anatomic scans (Figure 2) and reconstructed in three dimensions (3D). Based on these 3D reconstructions the esophagus insertion angle into the stomach was calculated (Figure 3). Intra-luminal pressure activity in the esophagus and proximal stomach was recorded continuously using HRM. Results: On dynamic MR images, reflux events were observed in 9 volunteers and all 6 GERD patients (Figure 4). The occurrence of reflux events correlated with intra-luminal pressure events recorded by HRM. The average number of reflux events over all volunteers was 2 (range 0-5) with the average duration of 10.7s (range 3-23s). In GERD patients the average number of reflux events was 4 (range 2-7) with the average duration of 24.4s (range 10-129s). The results for the insertion angle are given in Table 1. Discussion: The applied MRI technique allowed non-invasive assessment of the structure and function of the GEJ in healthy volunteers and GERD patients. Results showed increase in number and duration of reflux events for GERD patients compared to healthy volunteers. However the insertion angle was not different for health and disease (not statistically tested). A more detailed assessment of the structural composition of the GEJ is mandatory to gain more detailed insight and the understanding of the pathophysiology of GERD. In conclusion, MRI has the potential to become a valuable non-invasive technique in clinical routine for assessing GEJ disorders. References: [1] Fox M. et al. BMJ 332:88-93 (2006) [2] Holloway R. H. et al. Gastroenterology 89(4):779-84 (1985) [3] Trudgill N. J. et al. AmJGastroenterol 96(9):2569-74 (2001)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach

Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...

متن کامل

O-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis

Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...

متن کامل

Assessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques

The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...

متن کامل

The Assessment of Toxicity Characteristics of Cellular Uptake of Paramagnetic Nanoparticles as a New Magnetic Resonance Imaging Contrast Agent

Nanoparticles are unique that enable many promising medical and technological applications intheir physical, and chemical properties. It is widely accepted that nanoparticles should bethoroughly tested for health nanotoxicity, but a moderate risk analysis is currently prevented by arevealing absence of mechanistic knowledge of nanoparticle toxicity. The purpose of this study<b...

متن کامل

The Assessment of Toxicity Characteristics of Cellular Uptake of Paramagnetic Nanoparticles as a New Magnetic Resonance Imaging Contrast Agent

Nanoparticles are unique that enable many promising medical and technological applications intheir physical, and chemical properties. It is widely accepted that nanoparticles should bethoroughly tested for health nanotoxicity, but a moderate risk analysis is currently prevented by arevealing absence of mechanistic knowledge of nanoparticle toxicity. The purpose of this study<b...

متن کامل

CLINICAL CORRELATIONS BETWEEN AUDITORY BRAIN STEM RESPONSE AND MAGNETIC RESONANCE IMAGING IN PATIENTS WITH DEFINITE MULTIPLE SCLEROSIS

In an attempt to assess objectively the integrity of the auditory pathways in 30 patients with definite multiple sclerosis (MS), an audiometric evaluation was performed and auditory brainstem responses (ABRs) were obtained. Stressing the auditory system by increasing the stimulation rate showed some enhancement in the identification of MS. 24 (RO%) patients had an abnormal ABR along with c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008