A Comparison of Porcine Lens Storage Methods for Optimal Phacoemulsification

نویسندگان

  • Michael D Christensen
  • Sravanthi Vegunta
  • Alex Wright
  • Tyler Boulter
  • Brian Zaugg
  • Brian C Stagg
  • Jeff H Pettey
  • Randall J Olson
چکیده

Objective: The study purpose was to compare effects of two porcine lens storage methods on phacoemulsification efficiency and chatter. Methods: This in vitro laboratory study was conducted at the John A. Moran Eye Center Laboratories, University of Utah. Porcine nuclei were fixed in 10% formaldehyde and cut into 2.0 mm cubes. An equal number of lens cubes either were stored in a 100% humidity chamber or were partially immersed in balanced salt solution (BSS). Using identical parameters on the phacoemulsification machine, 40 lenses that underwent each storage method were phacoemulsified every two hours for a total of ten hours. Results: Lenses stored in the 100% humidity chamber experienced a 2.25% increase in efficiency per hour (r2=0.1922; p=0.3846), while lenses stored partially immersed in BSS experienced a 1.30% increase in efficiency per hour (r2=0.4084; p=0.1719). Although we found no statistically significant difference between the two groups, the partially immersed lenses were consistently softer than the lenses that were kept in the 100% humidity chamber. Chatter was minimal throughout the testing, but showed an increase over time. Conclusion: Either the 100% humidity chamber or the partially submerged method can be used for lens storage. Despite some differences between the two storage methodologies, the differences were not statistically significant. We conclude that using either method results in a natural softening of the lenses over time which must be taken into consideration during future experiments. This necessitates the testing time to be as short as possible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Entropic Imaging of Cataract Lens: An In Vitro Study

Phacoemulsification is a common surgical method for treating advanced cataracts. Determining the optimal phacoemulsification energy depends on the hardness of the lens involved. Previous studies have shown that it is possible to evaluate lens hardness via ultrasound parametric imaging based on statistical models that require data to follow a specific distribution. To make the method more system...

متن کامل

Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery.

PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...

متن کامل

Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems

PURPOSE To compare cumulative dissipated energy between two phacoemulsification machines. SETTING An ambulatory surgical center, Honolulu, Hawaii, USA. DESIGN Retrospective chart review. METHODS A total of 2,077 consecutive cases of cataract extraction by phacoemulsification performed by five surgeons from November 2012 to November 2014 were included in the study; 1,021 consecutive cases ...

متن کامل

Comparison of BD Multivisc with the soft shell technique in cases with hard lens nucleus and Fuchs endothelial dystrophy.

PURPOSE To compare the efficacy of 2.5% sodium hyaluronate (BD Multivisc) with the soft shell technique in reducing corneal endothelial cell damage during cataract phacoemulsification in patients with hard lens nucleus (3+) and cornea guttata. METHODS Thirty patients (37 eyes) scheduled for cataract surgery at Department of Ophthalmology and Visual Sciences, University Hospital San Raffaele, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016