Dosimetric impact of interplay effect on RapidArc lung stereotactic treatment delivery.

نویسندگان

  • ChinLoon Ong
  • Wilko F A R Verbakel
  • Johan P Cuijpers
  • Ben J Slotman
  • Suresh Senan
چکیده

PURPOSE Volumetric modulated arc therapy (RapidArc; Varian Medical Systems, Palo Alto, CA) allows fast delivery of stereotactic radiotherapy for Stage I lung tumors. We investigated discrepancies between the calculated and delivered dose distributions, as well as the dosimetric impact of leaf interplay with breathing-induced tumor motion. METHODS AND MATERIALS In 20 consecutive patients with Stage I lung cancer who completed RapidArc delivery, 15 had tumor motion exceeding 5 mm on four-dimensional computed tomography scan. Static and dynamic measurements were performed with Gafchromic EBT film (International Specialty Products Inc., Wayne, NJ) in a Quasar motion phantom (Modus Medical Devices, London, Ontario, Canada). Static measurements were compared with calculated dose distributions, and dynamic measurements were compared with the convolution of static measurements with sinusoidal motion patterns. Besides clinical treatment plans, additional cases were optimized to create excessive multileaf collimator modulation and delivered on the phantom with peak-to-peak motions of up to 25 mm. γ Analysis with a 3% dose difference and 2- or 1-mm distance to agreement was used to evaluate the accuracy of delivery and the dosimetric impact of the interplay effect. RESULTS In static mode film dosimetry of the two-arc delivery in the phantom showed that, on average, fewer than 3% of measurements had γ greater than 1. Dynamic measurements of clinical plans showed a high degree of agreement with the convolutions: for double-arc plans, 99.5% met the γ criterion. The degree of agreement was 98.5% for the plans with excessive multileaf collimator modulations and 25 mm of motion. CONCLUSIONS Film dosimetry shows that RapidArc accurately delivers the calculated dose distribution and that interplay between leaves and tumor motion is not significant for single-fraction treatments when RapidArc is delivered with two different arcs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer

PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...

متن کامل

A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours

BACKGROUND AND PURPOSE Stereotactic lung radiotherapy (SLRT) has emerged as a curative treatment for medically inoperable patients with early-stage non-small cell lung cancer (NSCLC) and the use of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc treatments (VMAT) have been proposed as the best practical approaches for the delivery of SLRT. However, a large number of narrow ...

متن کامل

Fractionated stereotactic radiotherapy of benign skull-base tumors: a dosimetric comparison of volumetric modulated arc therapy with Rapidarc® versus non-coplanar dynamic arcs.

BACKGROUND Benign tumors of the skull base are a challenge when delivering radiotherapy. An appropriate choice of radiation technique may significantly improve the patient's outcomes. Our study aimed to compare the dosimetric results of fractionated stereotactic radiotherapy between non-coplanar dynamic arcs and coplanar volumetric modulated arctherapy (Rapidarc®). METHODS Thirteen patients t...

متن کامل

A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams

To investigate potential dosimetric benefits and treatment efficiency of dynamic conformal arc therapy (DCA), intensity modulated radiation therapy (IMRT), and double partial arcs Rapidarc (RA) techniques in the treatment of early-stage peripheral lung cancer using stereotactic body radiotherapy (SBRT) with flattening filter free (FFF) beams. Twenty early-stage peripheral lung cancer patients w...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 79 1  شماره 

صفحات  -

تاریخ انتشار 2011