Wavelength-tuning interferometry of intraocular distances.

نویسندگان

  • F Lexer
  • C K Hitzenberger
  • A F Fercher
  • M Kulhavy
چکیده

We describe basic principles of wavelength-tuning interferometry and demonstrate its application in ophthalmology. The advantage of this technique compared with conventional low-coherence interferometry ranging is the simultaneous measurement of the object structure without the need for a moving reference mirror. Shifting the wavelength of an external-cavity tunable laser diode causes intensity oscillations in the interference pattern of light beams remitted from the intraocular structure. A Fourier transform of the corresponding wave-number-dependent photodetector signal yields the distribution of the scattering potential along the light beam illuminating the eye. We use an external interferometer to linearize the wave-number axis. We obtain high resolution in a model eye by slow tuning over a wide wavelength range. With lower resolution we demonstrate the simultaneous measurement of anterior segment length, vitreous chamber depth, and axial eye length in human eyes in vivo with data-acquisition times in the millisecond range.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precision Length Measurements by Multi-Wavelength Interferometry

Three different applications of multi-wavelength interferometry are reviewed which have been developed at PTB. They demonstrate the high precision achievable by this technique on multiple scales, from absolute geodetic distances up to 10 m, over prismatic bodies, e.g. gauge blocks, in the sub-meter regime, down to the microscopic roughness of surfaces.

متن کامل

Multi-Wavelength Interferometry for Length Measurements Using Diode Lasers

This paper describes the principle of precise length measurements using multi-wavelength interferometry. Three different examples are given in order to demonstrate PTB’s ability in this field: 1) Measurements of absolute distances up to 10 m performed by combination of the variable wavelength interferometry with fixed wavelength interferometry using two wavelengths simultaneously, 2) a three-wa...

متن کامل

Measurement and tuning of the chromatic dispersion of a silicon photonic wire around the half band gap spectral region.

We demonstrate the measurement and tuning of second-to-fourth order dispersion of a silicon wire waveguide in a spectral region of low nonlinear losses. Using white light interferometry we extract the chromatic dispersion of our waveguide from 1950 to 2300 nm. Moreover we demonstrate tuning of the zero dispersion wavelength over more than 100 nm, pushing it to longer wavelength by partially und...

متن کامل

Correction of sampling errors due to laser tuning rate fluctuations in swept-wavelength interferometry.

The frequency-sampling method is widely used to accommodate nonlinear laser tuning in swept-wavelength interferometric techniques such as optical frequency domain reflectometry (OFDR) and swept-wavelength optical coherence tomography (OCT). In this paper we analyze the frequency-sampling method and identify two sources of sampling errors. One source of error is the limit of an underlying approx...

متن کامل

Optical Interferometry

■ Abstract The field of optical and infrared (IR) interferometry has seen rapid technical and scientific progress over the past few years. A number of instruments capable of precise visibility measurements have been built, and closure-phase imaging with multitelescope arrays has been demonstrated. Astronomical results from these instruments include measurements of stellar diameters and their wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 36 25  شماره 

صفحات  -

تاریخ انتشار 1997