Rapid measurement of macronutrients in breast milk: How reliable are infrared milk analyzers?✩

نویسندگان

  • Gerhard Fusch
  • Niels Rochow
  • Arum Choi
  • Stephanie Fusch
  • Susanna Poeschl
  • Adelaide Obianuju Ubah
  • Sau-Young Lee
  • Preeya Raja
  • Christoph Fusch
چکیده

BACKGROUND & AIMS Significant biological variation in macronutrient content of breast milk is an important barrier that needs to be overcome to meet nutritional needs of preterm infants. To analyze macronutrient content, commercial infrared milk analyzers have been proposed as efficient and practical tools in terms of efficiency and practicality. Since milk analyzers were originally developed for the dairy industry, they must be validated using a significant number of human milk samples that represent the broad range of variation in macronutrient content in preterm and term milk. Aim of this study was to validate two milk analyzers for breast milk analysis with reference methods and to determine an effective sample pretreatment. Current evidence for the influence of (i) aliquoting, (ii) storage time and (iii) temperature, and (iv) vessel wall adsorption on stability and availability of macronutrients in frozen breast milk is reviewed. METHODS Breast milk samples (n = 1188) were collected from 63 mothers of preterm and term infants. Milk analyzers: (A) Near-infrared milk analyzer (Unity SpectraStar, USA) and (B) Mid-infrared milk analyzer (Miris, Sweden) were compared to reference methods, e.g. ether extraction, elemental analysis, and UPLC-MS/MS for fat, protein, and lactose, respectively. RESULTS For fat analysis, (A) measured precisely but not accurately (y = 0.55x + 1.25, r(2) = 0.85), whereas (B) measured precisely and accurately (y = 0.93x + 0.18, r(2) = 0.86). For protein analysis, (A) was precise but not accurate (y = 0.55x + 0.54, r(2) = 0.67) while (B) was both precise and accurate (y = 0.78x + 0.05, r(2) = 0.73). For lactose analysis, both devices (A) and (B) showed two distinct concentration levels and measured therefore neither accurately nor precisely (y = 0.02x + 5.69, r(2) = 0.01 and y = -0.09x + 6.62, r(2) = 0.02 respectively). Macronutrient levels were unchanged in two independent samples of stored breast milk (-20 °C measured with IR; -80 °C measured with wet chemistry) over a period of 14 months. CONCLUSIONS Milk analyzers in the current configuration have the potential to be introduced in clinical routine to measure fat and protein content, but will need major adjustments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LEVELS AND PREDICTORS OF MACRONUTRIENTS IN MATURE HUMAN MILK

Background & Aims: Breastfeeding is an important public health strategy due to its benefits in reducing the morbidity and mortality of infants and helping to control health care costs. Breastfeeding with various macronutrients and micronutrients plays its nutritional and biological roles in optimal growth and development of the infant. Based on the importance of breastfeeding, this study aimed...

متن کامل

Validation of Correction Algorithms for Near-IR Analysis of Human Milk in an Independent Sample Set—Effect of Pasteurization

Commercial infrared (IR) milk analyzers are being increasingly used in research settings for the macronutrient measurement of breast milk (BM) prior to its target fortification. These devices, however, may not provide reliable measurement if not properly calibrated. In the current study, we tested a correction algorithm for a Near-IR milk analyzer (Unity SpectraStar, Brookfield, CT, USA) for fa...

متن کامل

Target Fortification of Breast Milk: How Often Should Milk Analysis Be Done?

Target fortification (TFO) reduces natural macronutrient variation in breast milk (BM). Daily BM analysis for TFO increases neonatal intensive care unit work load by 10-15 min/patient/day and may not be feasible in all nurseries. The variation of macronutrient intake when BM analysis is done for various schedules was studied. In an observational study, we analyzed 21 subsequent samples of nativ...

متن کامل

Longitudinal Changes in the Macronutrient Contents of Breast Milk in the Mothers with Preterm Delivery

Background: Contents of breast milk may change during the first weeks after childbirth, especially in preterm deliveries. The present study aimed to determine the macronutrient contents of breast milk in the mothers with preterm delivery. Methods: This prospective-descriptive study was conducted in Mahdieh Hospital in Tehran, Iran in 2015. Participants included the mothers with preterm deliver...

متن کامل

Breast milk nutrient content and infancy growth

AIM Benefits of human breast milk (HM) in avoiding rapid infancy weight gain and later obesity could relate to its nutrient content. We tested the hypothesis that differential HM total calorie content (TCC) or macronutrient contents may be associated with infancy growth. METHODS HM hindmilk samples were collected at ages 4-8 weeks from 614 mothers participating in a representative birth cohor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2015