Prediction of atrial fibrillation in patients with an implantable cardioverter-defibrillator and heart failure.

نویسندگان

  • Matteo Bertini
  • C Jan Willem Borleffs
  • Victoria Delgado
  • Arnold C T Ng
  • Sebastiaan R D Piers
  • Miriam Shanks
  • M Louisa Antoni
  • Mauro Biffi
  • Giuseppe Boriani
  • Martin J Schalij
  • Jeroen J Bax
  • Nico R L Van de Veire
چکیده

AIMS Heart failure and atrial fibrillation (AF) frequently coexist and AF worsens heart failure prognosis. Device-based diagnostics derived from implantable cardioverter-defibrillator (ICD) interrogation provide an accurate method for detecting AF episodes. This study sought to determine clinical and echocardiographic predictors of AF occurrence, including an index of total atrial conduction time derived by tissue Doppler imaging (PA-TDI duration), in patients with heart failure. Moreover, the role of PA-TDI duration on the prediction of AF occurrence in subgroups of patients with and without history of AF was explored. METHODS AND RESULTS A cohort of 495 heart failure patients who underwent ICD implantation was studied. Baseline echocardiographic parameters of systolic and diastolic function were evaluated together with clinical parameters. Furthermore, PA-TDI duration was measured. All patients were prospectively followed up after ICD implantation for AF occurrence detected by ICD interrogation. A total of 142 (29%) patients experienced AF over a follow-up period of 16.4 ± 11.2 months. PA-TDI duration was longer in patients with AF occurrence when compared with patients without AF occurrence (154 ± 27 vs. 135 ± 24 ms, P < 0.001). On Cox-multivariable analysis, female gender [hazard ratio = 1.60; 95% confidence intervals (CI) = 1.09-2.35; P = 0.017], history of AF (hazard ratio = 2.22; 95% CI, 1.51-3.27; P < 0.001), and PA-TDI duration (hazard ratio = 1.27; 95% CI, 1.13-1.42; P < 0.001) were independent predictors of AF occurrence. In the subgroups of patients with and without history of AF, PA-TDI duration remained an independent predictor of AF occurrence. CONCLUSION PA-TDI duration may be useful to risk-stratify for AF occurrence in heart failure patients with and without a history of AF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Making a Splash?

ver the past decade, implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device platforms have been expanded to include a host of new integrated device-based diagnostic capabilities.1 Parameters such as a sustained drop in intrathoracic impedance, reduced heart rate variability, high resting heart rate, decreased patient activity, prolonged periods of atrial...

متن کامل

Atrial fibrillation had a negative impact on quality of life, and treatment with an implantable cardioverter defibrillator with atrial therapies helped patients regain a sense of normalcy.

Deaton C, Dunbar SB, Moloney M, et al. Patient experiences with atrial fibrillation and treatment with implantable atrial defibrillation therapy. Heart Lung 2003;32:291–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

متن کامل

Combined Heart Failure Device Diagnostics Identify Patients at Higher Risk of Subsequent Heart Failure Hospitalizations

Methods The PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) was a prospective, multicenter observational study in patients receiving cardiac resynchronization therapy (CRT) implantable cardioverter-defibrillators. HF events were independently adjudicated. A combined HF device diagnostic algorithm was developed o...

متن کامل

Atrial fibrillation in patients with implantable defibrillators.

Atrial fibrillation (AF) is common in patients who have implantable defibrillators and presents some unique challenges and opportunities. AF burden can be assessed more accurately, allowing for evaluation of therapy efficacy (drugs or ablation). It remains to be shown whether home monitoring of defibrillators to detect and treat AF more quickly can reduce cardiovascular and stroke end points. O...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of heart failure

دوره 12 10  شماره 

صفحات  -

تاریخ انتشار 2010