Reevaluation of absolute luminescence quantum yields of standard solutions using a spectrometer with an integrating sphere and a back-thinned CCD detector.
نویسندگان
چکیده
We reevaluate the absolute fluorescence and phosphorescence quantum yields of standard solutions by using a novel instrument developed for measuring the absolute emission quantum yields of solutions. The instrument consists of an integrating sphere equipped with a monochromatized Xe arc lamp as the light source and a multichannel spectrometer. By using a back-thinned CCD (BT-CCD) as the detector, the sensitivity for spectral detection in both the short and long wavelength regions is greatly improved compared with that of an optical detection system that uses a conventional photodetector. Using this instrument, we reevaluate the absolute fluorescence quantum yields (Phi(f)) of some commonly used fluorescence standard solutions by taking into account the effect of reabsorption/reemission. The value of Phi(f) for 5 x 10(-3) M quinine bisulfate in 1 N H(2)SO(4) is measured to be 0.52, which is in good agreement with the value (0.508) obtained by Melhuish by using a modified Vavilov method. In contrast, the value of Phi(f) for 1.0 x 10(-5) M quinine bisulfate in 1 N H(2)SO(4), which is one of the most commonly used standards in quantum yield measurements based on the relative method, is measured to be 0.60. This value is significantly larger than Melhuish's value (0.546), which was estimated by extrapolating the value of Phi(f) for 5 x 10(-3) M quinine bisulfate solution to infinite dilution using the self-quenching constant. The fluorescence quantum yield of 9,10-diphenylanthracene in cyclohexane is measured to be 0.97. This system can also be used to determine the phosphorescence quantum yields (Phi(p)) of metal complexes that emit phosphorescence in the near-infrared region: the values of Phi(p) for [Ru(bpy)(3)](2+) (bpy = 2,2'-bipyridine) are estimated to be 0.063 in water and 0.095 in acetonitrile under deaerated conditions at 298 K, while that in aerated water, which is frequently used as a luminescent reference in biological studies, is reevaluated to be 0.040.
منابع مشابه
Measurement of the Fluorescence Quantum Yield Using a Spectrometer With an Integrating Sphere Detector
A method is proposed for measuring the fluorescence quantum yield (QY) using a commercial spectrophotometer with a 150 mm integrating sphere (IS) detector. The IS detector is equipped with an internal cuvette holder so that absorbance measurements can be performed with the cuvette inside the IS. In addition, the spectrophotometer has a cuvette holder outside the IS for performing conventional a...
متن کاملPhotophysics on surfaces: determination of absolute fluorescence quantum yields from reflectance spectra.
A method for the calculation of absolute fluorescence quantum yields for dyes attached to solid particles based on reflectance measurements is reported. The same procedure allows calculation of true reflectance spectra (free of fluorescence) for highly fluorescent materials as well. Samples ofcresyl violet were immobilized by adsorption on microgranular cellulose in the concentration range 4.5 ...
متن کاملSelf-absorption correction for solid-state photoluminescence quantum yields obtained from integrating sphere measurements.
A new method is presented for analyzing the effects of self-absorption on photoluminescence integrating sphere quantum yield measurements. Both the observed quantum yield and luminescence spectrum are used to determine the self-absorption probability, taking into account both the initial emission and subsequent absorption and reemission processes. The analysis is experimentally validated using ...
متن کاملIntrinsic quantum yields and radiative lifetimes of lanthanide tris(dipicolinates).
The efficiency with which the surroundings of trivalent lanthanide ions sensitize their luminescence (eta(sens)) is a key parameter in the design of highly emitting molecular edifices and materials. Evaluation of eta(sens) requires the measurement of the overall and intrinsic quantum yields obtained upon ligand and metal excitation, respectively. We describe a modified integration sphere enabli...
متن کاملDetector-Based Luminous Flux Calibration using the Absolute Integrating-Sphere Method
The Absolute Integrating-Sphere Method was developed and introduced by NIST for the realization of the luminous flux unit using an integrating sphere rather than a goniophotometer. The total luminous flux of a lamp inside the sphere is calibrated against the known amount of flux introduced into the sphere from the external source through a calibrated aperture. The key element of this method is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical chemistry chemical physics : PCCP
دوره 11 42 شماره
صفحات -
تاریخ انتشار 2009