Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Evidence-Based Analysis.
ثبت نشده
چکیده
BACKGROUND Colorectal cancer, a leading cause of mortality and morbidity in Ontario, can be prevented through early diagnosis and removal of precancerous polyps. Colon capsule endoscopy is a relatively new, minimally invasive test for detecting colorectal polyps. OBJECTIVE The objectives of this analysis were to evaluate the diagnostic accuracy and safety of colon capsule endoscopy for the detection of colorectal polyps among adult patients with signs or symptoms of colorectal cancer or with increased risk of colorectal cancer, and to compare colon capsule endoscopy with alternative procedures. REVIEW METHODS A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid EMBASE, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2006 and 2014. Data on diagnostic accuracy and safety were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). RESULTS The search yielded 2,189 citations. Five studies, all of which evaluated PillCam COLON 2 (PCC2), met the inclusion criteria. The per-patient sensitivity and specificity for detecting colorectal polyps were meta-analyzed. Colon capsule endoscopy, using PCC2, had a pooled sensitivity and specificity of 87% (95% confidence interval [CI] 77%-93%) and 76% (95% CI 60%-87%), respectively, for the detection of a colorectal polyp at least 6 mm in size (GRADE: very low). PCC2 had a pooled sensitivity and specificity of 89% (95% CI 77%-95%) and 91% (95% CI 86%-95%), respectively, for the detection of a colorectal polyp at least 10 mm in size (GRADE: low). One study directly compared PCC2 with computed tomographic (CT) colonography and found no statistically significant difference in accuracy (GRADE: low). Few adverse events were reported with PCC2; 3.9% of patients (95% CI 2.4%-6.5%) experienced adverse effects related to bowel preparation. Capsule retention was the most serious adverse event and occurred in 0.8% of patients (95% CI 0.2%-2.4%) (GRADE: very low). CONCLUSIONS In adult patients with signs, symptoms, or increased risk of colorectal cancer, there is low-quality evidence that colon capsule endoscopy using the PCC2 device has good sensitivity and specificity for detecting colorectal polyps. Low-quality evidence does not show a difference in accuracy between colon capsule endoscopy and CT colonography. There is very low-quality evidence that PCC2 has a good safety profile with few adverse events; capsule retention is the most serious complication.
منابع مشابه
Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis.
BACKGROUND Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. OBJECTIVES The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario hea...
متن کاملCapsule endoscopy versus colonoscopy for the detection of polyps and cancer.
BACKGROUND An ingestible capsule consisting of an endoscope equipped with a video camera at both ends was designed to explore the colon. This study compared capsule endoscopy with optical colonoscopy for the detection of colorectal polyps and cancer. METHODS We performed a prospective, multicenter study comparing capsule endoscopy with optical colonoscopy (the standard for comparison) in a co...
متن کاملDetection and Classification of Human Colorectal Polyps
In this thesis we address the problem of segmentation and detection of colorectal polyps in endoscopic images obtained by a wireless capsule endoscopic device. As colorectal polyps are precursors to colonic cancer, and an early detection and removal of colorectal polyps can positively affect the prognosis of colonic cancer (one of the leading causes of death by cancer), it is our goal to develo...
متن کاملAutomatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
Background. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption that the polyps show up as a protrusion in the captured images and is expressed by means of a P-v...
متن کاملSecond-generation colon capsule endoscopy compared with colonoscopy.
BACKGROUND Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE To assess the feasibility, accu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ontario health technology assessment series
دوره 15 14 شماره
صفحات -
تاریخ انتشار 2015