Benefits of monitoring patients with mobile cardiac telemetry (MCT) compared with the Event or Holter monitors

نویسندگان

  • Jean-Patrick Tsang
  • Shunmugam Mohan
چکیده

INTRODUCTION This research is meant to establish if a patient monitored with mobile cardiac telemetry (MCT) sees different outcomes regarding diagnostic yield of arrhythmia, therapeutic management through the use of antiarrhythmic drugs, and cardiovascular costs incurred in the hospital setting when compared with more traditional monitoring devices, such as the Holter or the Event monitor. MATERIALS AND METHODS We conducted a retrospective analysis spanning 57 months of claims data from January 2007 to September 2011 pertaining to 200,000+ patients, of whom 14,000 used MCT only, 54,000 an Event monitor only, and 163,000 a Holter monitor only. Those claims came from the Truven database, an employer database that counts 2.8 million cardiovascular patients from an insured population of about 10 million members. We employed a pair-wise pre/post test-control methodology, and ensured that control patients were similar to test patients along the following dimensions: age, geographic location, type of cardiovascular diagnosis both in the inpatient and outpatient settings, and the cardiovascular drug class the patient uses. RESULTS First, the diagnostic yield of patients monitored with MCT is 61%, that is significantly higher than that of patients that use the Event monitor (23%) or the Holter monitor (24%). Second, patients naive to antiarrhythmic drugs initiate drug therapy after monitoring at the following rates: 61% for patients that use MCT compared with 39% for patients that use the Event and 43% for patients that use the Holter. Third, there are very significant inpatient cardiovascular savings (in the tens of thousands of dollars) for patients that undergo ablation, coronary artery bypass graft (CABG) and valve septa. Savings are more modest but nonetheless significant when it comes to the heart/pericardium procedure. CONCLUSION Given the superior outcome of MCT regarding both patient care and hospital savings, hospitals only stand to gain by enforcing protocols that favor the MCT system over the Event or the Holter monitor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac event recorders yield more diagnoses and are more cost-effective than 48-hour Holter monitoring in patients with palpitations. A controlled clinical trial.

OBJECTIVE To compare the diagnostic yield and cost-effectiveness of transtelephonic event monitors with those of Holter monitoring in patients with intermittent palpitations. DESIGN Randomized crossover trial. SETTING Diagnostic service of a teaching hospital and surrounding primary care practices. PATIENTS 43 patients with previously uninvestigated palpitations who were referred for Holt...

متن کامل

The diagnosis of cardiac arrhythmias: a prospective multi-center randomized study comparing mobile cardiac outpatient telemetry versus standard loop event monitoring.

INTRODUCTION Ambulatory electrocardiographic monitoring systems are frequently used in the outpatient evaluation of symptoms suggestive of a cardiac arrhythmia; however, they have a low yield in the identification of clinically significant but infrequent, brief, and/or intermittently symptomatic arrhythmias. The purpose of this study was to compare the relative value of a mobile cardiac outpati...

متن کامل

Ambulatory External Electrocardiographic Monitoring

There has been progressive development in ambulatory external electrocardiogram (AECG) monitoring technology. AECG monitors initially consisted of 24to 48-h Holter monitors and patient-activated event and loop recorders. More recently, several ambulatory cardiovascular telemetry monitors and a patch-type 7to 14-day Holter monitor have been introduced. These monitoring systems are reviewed along...

متن کامل

Cardiac workup of ischemic stroke: can we improve our diagnostic yield?

BACKGROUND AND PURPOSE Discovering potential cardiac sources of stroke is an important part of the urgent evaluation of the ischemic stroke patient as it often impacts treatment decisions that are essential for determining secondary stroke prevention strategies, yet the optimal approach to the cardiac workup of an ischemic stroke patient is not known. METHODS A review of the literature concer...

متن کامل

Response to the letter regarding article, "Occult atrial fibrillation in cryptogenic stroke: detection by 7-day electrocardiogram versus implantable cardiac monitors".

BACKGROUND AND PURPOSE A significant number of patients with cryptogenic stroke suffer from intermittent atrial fibrillation (iAF) which was not detected during the standard diagnostic procedures. We investigated whether implantation of an insertable cardiac monitor (ICM) is feasible in patients with cryptogenic stroke, and compared the iAF detection rate of the ICM with 7-day Holter monitoring...