Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.

نویسندگان

  • J P Brody
  • R Valdes
  • J Savory
چکیده

We describe two centrifugal analyzer methods for measuring total bilirubin in serum. Diazotized 2-chloroaniline-5-sulfonic acid is used in both. In the first procedure, ethylene glycol and methanol are used as an accelerator solvent; results correlate well with those by a Jendrassik and Grof method adapted to the centrifugal analyzer, but there is considerable hemolysis interference. In the second method, dimethyl sulfoxide is used with the ethylene glycol/methanol solvent and almost all hemolysis interference is eliminated. For either method, a 15-microliter sample is required. In the second method, instrument response is linearly related to concentration to 250 mg/L and the within-run precision (CV) is about 1%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.

A procedure has been developed for the automated measurement of conjugated bilirubin in serum with a centrifugal analyzer. The conjugated bilirubin is measured by a fixed time kinetic method which monitors the reaction between conjugated bilirubin and diazotized sulfanilic acid at 550 nm. Results are calculated based on a comparison of the reagent blank-corrected absorbance changes between 15 s...

متن کامل

Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.

We automated the Jendrassik-Grof method for measurement of bilirubin with the Greiner Selective Analyzer GSA II D. Comparison with the manual Jendrassik-Grof method showed a highly significant correlation coefficient of 0.994 for total and 0.980 for "direct" bilirubin measurement. The automated method showed good precision and was linear to 667 mu mol/L, the highest concentration tested. Additi...

متن کامل

Adaptation of blank-corrected methods for measurement of total and conjugated bilirubin and uric acid to the centrifugal analyzer.

The blank-corrected determination in serum of total and conjugated bilirubin and of uric acid has been adapted to the centrifugal analyzer. Bilirubin is measured by a modified Jendrassik and Grof procedure; uric acid is determined kinetically by using a reaction based on reduction of ferric ion, including a uricase-treated blank. Sensitivity and precision of both methods are excellent, and resu...

متن کامل

Inaccurate values for direct bilirubin with some commonly used direct bilirubin procedures.

We compared five methods for the determination of total and direct bilirubins in serum samples from normal controls, subjects with Gilbert's syndrome, and serum pools containing about 50 and 150 mg of total bilirubin per liter. The Kodak Ektachem method and a diazotized sulfanilic acid method with 0.15 mmol/L sodium nitrite concentrations are the only methods that gave accurate direct bilirubin...

متن کامل

New kinetic method for creatinine measurement now automated in the Cobas Fara centrifugal analyzer.

A new kinetic method to determine creatimne in serum by using an alkaline 3,5-dinitrobenzoate solution was recently reported (1). Interference from pseudo-creatinine chromogens, bilirubin, or triacylglycerols was negligible. The results obtained with this kinetic spectrophotometric assay, performed with an Eppendorf ACP 5040 analyzer, agreed well with the procedure of Jaff#{233}, as modified by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 1979