Determination of direct oral anticoagulants from human serum samples.

نویسندگان

  • Job Harenberg
  • Sandra Kraemer
  • Shanshan Du
  • Christina Giese
  • Astrid Schulze
  • Roland Kraemer
  • Christel Weiss
چکیده

Dabigatran, rivaroxaban, and apixaban are direct oral anticoagulants (DOAC) inhibiting thrombin or factor Xa and effectively preventing thromboembolic complications using fixed doses without need for laboratory-guided dose adjustment. Plasma samples are needed to determine the actual concentration or activity of DOACs, which may be required for special patient populations such as those with acute deterioration of renal function due to any disease, before surgical interventions, during bleeding or thrombotic episodes while on therapy with DOACs, the elderly and youngest populations, unexpected pregnancy, suspicion of overdose and toxication, and to control adherence to therapy. Serum samples have several advantages over plasma samples such as no need of sampling with a specific coagulation tube, reduced pre-analytical errors, and longer storage stability. Determination of rivaroxaban and apixaban from serum samples of patients on treatment performed well and better than samples of patients treated with dabigatran compared with plasma samples. Specific adaption to automated coagulation platforms may improve the performance of the assays from serum samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patients' serum and urine as easily accessible samples for the measurement of non-vitamin K antagonist oral anticoagulants.

Measurement of the anticoagulant effect of non-vitamin K antagonist oral anticoagulants (NOAC) may be desirable, in particular in patients with acute medical conditions. Useful methods should give results rapidly within minutes, should be easy to perform, specific, and sensitive. Using plasma samples, chromogenic assays can be made to be specific for the two types of NOAC (factor Xa and thrombi...

متن کامل

Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...

متن کامل

Laboratory testing in the era of direct or non-vitamin K antagonist oral anticoagulants: a practical guide to measuring their activity and avoiding diagnostic errors.

A new generation of antithrombotic agents has recently emerged. These provide direct inhibition of either thrombin (factor IIa [FIIa]) or FXa, and are increasingly replacing the classical anticoagulants (heparin and coumarins such as warfarin) in clinical practice for a variety of conditions. These agents have been designated several acronyms, including NOACs, DOACs, and TSOACs, respectively, r...

متن کامل

Combined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy

This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...

متن کامل

Combined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy

This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Seminars in thrombosis and hemostasis

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2014