Installation of spectrally selective imaging system in RF negative ion source.
نویسندگان
چکیده
A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (Hα) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of Hα emission near the bias plate has been clearly observed. The same time trend on Hα intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.
منابع مشابه
An Automatic Real Time Impedance Matching System for Use in an RF Electrostatics Accelerator Ion Source
متن کامل
Development Strategy of RF Ion Source for Neutral Beam Injector in Fusion Devices
Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER device [1, 2]. Negative hydrogen ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck-Institute for Plasma ...
متن کاملPhysical Performance Analysis And The Progress Of The Development Of The Negative Ion RF Source For The ITER NBI System
For heating and current drive the neutral beam injection system for ITER requires a 1 MeV deuterium beam for up to 1 h pulse length. In order to inject the required 17 MW the large area source (1.9m x 0.9m) has to deliver 40 A of negative ion current at the specified source pressure of 0.3 Pa. In 2007 the IPP RF driven negative hydrogen ion source was chosen as the new reference source for the ...
متن کاملSelective MRI of magnetically labeled cells – a comparative evaluation of positive contrast techniques
J-H. Seppenwoolde, R. Oude Engberink, A. van der Toorn, E. L. Blezer, C. J. Bakker Image Sciences Institute / Dept. of Radiology, University Medical Center Utrecht, Utrecht, Netherlands Introduction – For the detection and visualization of SPIO-labeled cells or clusters of USPIOs, T2*-weighted imaging is generally used. A clear disadvantage of using T2* weighted techniques is the detection of t...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 87 2 شماره
صفحات -
تاریخ انتشار 2016