Maximal expiratory flow-volume loop in a southern Indian college sportsmen.

نویسندگان

  • K V Rao
  • V K Vijayan
چکیده

Flow volume loops using computerised pulmonary function testing equipment were analysed in twenty sportsmen of Loyola College, Madras. There was no significant difference in mean P.E.F.R. (P greater than 0.2) and VE 25% (P greater than 0.2) in sportsmen, compared to Indian or American normals. On the other hand, the mean VE 50% (P less than 0.05) and VE 75% (P less than 0.001) were significantly higher in sportsmen compared to Indian values, but was similar to those reported in American normals (P greater than 0.1). Inspiratory flow rates were similar to those reported in Indians. Our results show that there is an increase in maximal expiratory flow rates at lower lung volumes in Southern Indian College Sportsmen compared to Indian normals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary functions in Indian sportsmen playing different sports.

Regular exercise has proved to be beneficial for the human body and the lungs are no exception. The present study was undertaken to assess the relation between the quality of exercise performed and the quantitative effect of these exercises on the lungs. Pulmonary function tests of sportsmen engaged in various sports were compared with each other and with that of the controls. Players playing f...

متن کامل

SMOKING AND LUNG FUNCTIONS IN SPORTSMEN A. K. DE and M. M. TRIPATHI* Unit of Sports Medicine and Pulmonary Physiology and Department of Respiratory Diseases and Tuberculosis

Ten smoker sportsmen and 17 non-smoker sportsmen and 41 smoker non-sportsmen were studied. Lung function was assessed by means of Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEVj), the ratio of FEV1 to FVC (FEV,%) and Peak Expiratory Flow Rate (PEFR). For the smokers, all the tests were conducted before smoking (BS) and 30 min after smoking (AS) two cigarettes consecuti...

متن کامل

The flow volume loop: normal standards and abnormalities in chronic obstructive pulmonary disease.

The flow-volume loop is a test of ventilatory function in which a graphic recording of maximal flow rates is dispiayed at all lung volumes during a maximal effort forced expiratory and inspiratory vital capacity maneuver. The test is errsy to demonstrate, administer, and analyze. Pulmonary diseases produce characteristic flow-volume loop abnormalities. The visualization of abnormalities and cal...

متن کامل

Spirometry versus flow volume inspiratory and expiratory loop.

P SPIROMETRY VERSUS FLOW VOLUME INSPIRATORY AND EXPIRATORY LOOP To the Editor: I would like to comment on the excellent CME article, “Vocal Cord Dysfunction: An Update” by Leslie M. Gimenez, MD, and Heidi Zafra, MD (Ann Allergy Asthma Immunol. 2011;106:267–275). I compliment the authors on the very thorough review and analysis of the literature. I am concerned by the nomenclature they used in d...

متن کامل

Effect of gender and body mass index on pulmonary function tests in adolescents of tribal population of a north eastern state of India.

The present study was planned to assess the pulmonary function in tribal adolescents (age 12-16 yrs) of Tripura, a north eastern state of India, and to evaluate the effect of body mass index (BMI) on pulmonary functions of male and female subjects from tribal population. One hundred and seventeen male and seventy female subjects were selected for the study through a randomized method of samplin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Indian journal of physiology and pharmacology

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 1988