Induced signals in resistive plate chambers
نویسنده
چکیده
We derive theorems for induced signals on electrodes embedded in a medium with a position and frequencydependent permittivity eð~x; sÞ and conductivity sð~x; sÞ that are connected with arbitrary discrete elements. The problem is treated using the quasi-static approximation of Maxwell’s equations for weakly conducting media. The induced signals can be derived by time-dependent weighting fields and potentials and the result is the same as the one given in Gatti et al. (Nucl. Instr. and Meth. 193 (1982) 651). We also show how these time-dependent weighting fields can be derived from electrostatic solutions. Finally, we will apply the results to Resistive Plate Chambers where we discuss the effects of the resistive plates and thin resistive layers on the signals induced on plane electrodes and strip electrodes. r 2002 Published by Elsevier Science B.V. PACS: 07.05.Tp; 29.40.Cs; 29.40.Gx
منابع مشابه
Observation of light from resistive plate chambers
Electrically induced signals and light emissions from Restrictive Plate Chamber (RPC) are simultaneously measured using a glass RPC with transparent high-voltage planes, operating in the streamer mode. With one exception, good correspondence is seen in between the electrical and optical signals in every aspect: signal shapes, pulse heights, timing and afterpulses. The one exception is a possibl...
متن کامل. in s - de t ] 1 8 Ju l 2 00 8 Simple Front End Electronics for Multigap Resistive Plate Chambers
A simple circuit for the presentation of the signals from Multi-gap Resistive Plate Chambers (MRPCs) to standard existing digitization electronics is described. The circuit is based on “off-the-shelf” discrete components. An optimization of the values of specific components is required to match the aspects of the MRPCs for the given application. This simple circuit is an attractive option for t...
متن کاملResistive plate chambers performances at cosmic rays fluxes
In this paper detailed curves showing the behaviour of resistive plate chambers efficiency and time resolution as a function of temperature and operating voltage are presented. The results show that the operating voltage scales well according to the rule: operating voltage/gas density = constant.
متن کاملResistive Plate Chamber Performance in the BaBar IFR System
The BaBar Collaboration has operated a system covering over 2000 m with resistive plate chambers for nearly three years. The chambers are constructed of bakelite sheets separated by 2 mm. The inner surfaces are coated with linseed oil. This system provides muon and neutral hadron detection for BaBar. Installation and commissioning were completed in 1998, and operation began mid-1999. While init...
متن کاملStudy of the Resistive Plate Chambers for the ALICE Dimuon Arm
The trigger system for the ALICE Dimuon Arm will be based on Resistive Plate Chambers. A RPC prototype, with electrodes made of low resistivity bakelite (ρ ∼ 3·109Ωcm) has been tested both at the SPS and at the GIF. The results for operation in streamer mode are presented here.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -