Adhesive systems used for sealing contaminated surfaces: a microleakage evaluation.

نویسندگان

  • Rosa Helena Miranda Grande
  • Alessandra Reis
  • Alessandro Dourado Loguercio
  • Julio da Motta Singer
  • Edward Shellard
  • Paulo Christino Neto
چکیده

The aim of this study was to compare two adhesive systems (OptiBond FL and OptiBond SOLO) used as a sole material for sealing pit and fissures on contaminated surfaces with respect to microleakage. After acid etching, 56 sound teeth were contaminated with 1microl of plasma and randomly divided into 8 groups (n = 7). The adhesives were light activated under two conditions (Optilux VCL-403 and VCL-500) for 30 s. Each specimen was exposed to one of the following aging treatments: thermal (4,000 X at 5-55 degrees C for 60 s) plus load cycling (225,000 X with 83.3 N) or thermal plus load and pH cycling (mineralizing/demineralizing solutions). Then, they were immersed in a 50% AgNO3 aqueous solution, sectioned twice and had dye penetration measured through digitized images. ANOVA methods were used to assess the main effects of the factors as well as their interactions. The results indicated a significant difference between the adhesive systems (p < 0.05), suggesting that OptiBond FL has a better performance with respect to microleakage and could be used as a sealing material in accidentally moist or contaminated surfaces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of self-adhering composite microleakage compared with tow conventional adhesive systems

Background and Aims: The self-adhering composites were introduced to reduce the chair time and minimizing handling errors. They can be bonded micromechanically to the dental structure without the need for separate adhesive application. Since there is limited information about bonding performance of this type of composite, the aim of this study was to evaluate the microleakage of enamel and dent...

متن کامل

Evaluation of shear bond strength and microleakage of deproteinized dentin bonded with three total-etch adhesive systems

Purpose: To evaluate the effect of NaOCl conditioning on shear bond strength and marginal sealing of resin bonded dentin with three total-etching adhesive systems. Materials and Methods: Flat dentin surfaces were prepared and received the following treatments: Group I, 35% phosphoric acid for 15 s; Group II, 35% phosphoric acid for 15 s followed by 10% NaOCl for 60 s; Group III received no addi...

متن کامل

Effect of Saliva Contamination on Microleakage Beneath Bonded Brackets: A Comparison Between Two Moisture-Tolerant Bonding Systems

OBJECTIVES This study aimed to evaluate the effects of saliva contamination on the metallic bracket microleakage bonded with two moisture-tolerant bonding systems. MATERIALS AND METHODS Ninety freshly extracted premolar teeth were randomly divided into six groups of 15 with the following treatments: G1 (control): After acid etching, Assure primer and Assure adhesive were applied to non-contam...

متن کامل

Effect of a plant-based hemostatic agent on microleakage of self-etching adhesives

OBJECTIVE This in vitro study evaluated the effect of Ankaferd Blood Stopper (ABS) contamination on the microleakage of one-step and two-step self-etching adhesives. STUDY DESIGN Class V cavities were prepared at the cemento-enamel junction on both buccal and lingual surfaces of 60 freshly extracted human molars. Teeth were randomly assigned into three groups according to contamination materi...

متن کامل

Microleakage evaluation of core buildup composite resins with total-etch and self-etch adhesive systems.

AIM Core buildup composite resins with prefabricated posts are commonly used to restore endodontically treated teeth. This study compared the sealing ability of Core Max II and Panavia F2.0 cement with total-etch and self-etch adhesive systems. METHODS AND MATERIALS Sixty recently extracted human second premolar teeth were chosen and their crowns were cut 3 mm above the CEJ. After preparing p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian oral research

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2005