Effect of glide path preparation on apical extrusion of debris in root canals instrumented with three single-file systems: An ex vivo comparative study

نویسندگان

  • Ajinkya M. Pawar
  • Mansing Pawar
  • Anda Kfir
  • Bhagyashree Thakur
  • Pooja Mutha
  • Kulwinder Singh Banga
چکیده

AIM The aim of this study was to test the effect of new protocol of glide path preparation by 20/0.04 rotary file on apical extrusion of debris when instrumenting fine curved mesial canals in mandibular molars with Self-adjusting File (SAF) and compare it to a glide path prepared by 20/0.02 hand K-file and rotary OneShape (OS) and reciprocating WaveOne (WO) file instrumentation. MATERIALS AND METHODS Sixty mandibular molars with curved mesial roots were selected and randomly divided into three groups (n = 20) for instrumentation. In two groups, glide path was prepared using 20/0.02 K-file for instrumentation by OS (size 25/0.06 taper) and WO (size 25/0.08 taper) files; in the remaining group, 20/0.04 rotary file was used for glide path preparation and instrumented by SAF (1.5 mm). The debris extruded during instrumentation was collected in preweighed Eppendorf tubes and stored in an incubator at 70°C for 5 days. Tubes containing the dry extruded debris were then weighed. One-way analysis of variance (ANOVA) was applied to the weights obtained, followed by Tukey's post hoc test for multiple comparison. RESULTS The mean debris (g) extruded apically was 0.000651 ± 0.000291, 0.000823 ± 0.000319, and 0.000473 ± 0.000238 for Group 1 (20/0.02 + OS), Group 2 (20/0.02 + WO), and Group 3 (20/0.04 + SAF), respectively. The groups exhibited a significant difference (P < 0.01; ANOVA). Group 3 resulted in least debris extrusion compared to Groups 1 and 2 (P < 0.01; Tukey's post hoc test). CONCLUSION Glide path prepared to size 20/0.04 and SAF 1.5 mm instrumentation produce less debris in curved mesial canals of mandibular molars, compared to glide path established by 20/0.02 and instrumentation by OS and WO files.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of apical debris extrusion between RaCe and Komet F6 An Ex-Vivo Study

Background & Aim: Apical extrusion of debris is one of the reasons for flare-up(pain,swelling,or both). This study aimed to determine the apical debris extrusion of two rotary systems(RaCe and Komet F6 SkyTaper) in curved mesiobuccal canals of mandibular first molars. Material and methods: Thirty mandibular first molars (with mesiobuccal canal curvature 25-35 degree) were included in this ex...

متن کامل

Effect of coronal flaring on apical extrusion of debris during root canal instrumentation using single-file systems.

AIM To evaluate the effect of coronal flaring on the amount of debris extruded apically during root canal preparation using the Reciproc, WaveOne (WO) and OneShape (OS) single-file systems. METHODOLOGY Ninety extracted single-rooted mandibular incisor teeth were randomly assigned to six groups (n = 15 for each group) for canal instrumentation. Endodontic access cavities were prepared in each ...

متن کامل

Efficacy of XP-Endo Finisher R File in the Removal of Gutta-percha residue after root canal retreatment: an experimental study

Background and Aim: Complete removal of gutta-percha from the root canal system and its remnants is a challenge in endodontic retreatment. This ex-vivo study aimed to assess the efficacy of XP-Endo Finisher R (XEFR) in removing root filling remnants from straight canals of mandibular premolars in root canal retreatment.   Materials and Methods: In this ex-vivo study, 30 single-rooted mandib...

متن کامل

Comparison of WaveOne and ProTaper Universal Preparation Systems in the Amount of Smear Layer/Debris Production: an in-vitro SEM Study

Background and Aim: Debris and the smear layer that remain after root canal preparations may result in failure of root canal therapies. The aim of this study was to compare the smear layer formation and the amount of residual debris following the use of WaveOne and ProTaper rotary files in mesiobuccal root canals of upper first molars by scanning electron microscopy (SEM). Materials and Method...

متن کامل

An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography

Background and purpose: The purpose of mechanical cleaning of the root canal is to clean the canal walls, create a conical shape to facilitate access, effective washing, and filling all areas of the root canal. Errors such as root canal transportation are cuased by excessive dentin removal from the canal. The objective of this study was to investigate root canal transportation by a BT Race rota...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2017