Bioequivalence of HX575 (recombinant human epoetin alfa) and a comparator epoetin alfa after multiple intravenous administrations: an open-label randomised controlled trial

نویسندگان

  • Fritz Sörgel
  • Ursula Thyroff-Friesinger
  • Andrea Vetter
  • Bernhard Vens-Cappell
  • Martina Kinzig
چکیده

BACKGROUND HX575 is a human recombinant epoetin alfa that was approved for use in Europe in 2007 under the European Medicines Agency biosimilar approval pathway. Therefore, in order to demonstrate the bioequivalence of HX575 to an existing epoetin alfa, the pharmacokinetic and pharmacodynamic response to steady state circulating concentrations of HX575 and a comparator epoetin alfa were compared following multiple intravenous administrations. METHODS An open, randomised, parallel group study was conducted in 80 healthy adult males. Subjects were randomised to multiple intravenous doses of 100 IU/kg body weight of HX575 or of the comparator epoetin alfa three-times-weekly for four weeks. Serum epoetin concentrations were measured using an enzyme-linked immunosorbent assay and pharmacokinetic parameters for the two treatments were compared. The time course and area under the effect curve ratio of haematological characteristics were used as surrogate parameters for efficacy evaluation. RESULTS The haematological profiles of both treatments were similar, as determined from their population mean curves and the AUECHb ratio and 90% confidence interval (99.9% [98.5-101.2%]), the primary pharmacodynamic endpoint of this study. The pharmacokinetic parameters after the treatments showed minor differences after single dosing, but not at steady state doses. After multiple doses, HX575 was bioequivalent to the comparator with respect to the rate and extent of exposure of exogenous epoetin (AUCtau ratio and 90% confidence interval: 89.2% [82.5-96.2%]). Study medication was well tolerated with no clinically relevant differences between safety profiles of the treatments. Anti-epoetin antibodies were not detected. CONCLUSION HX575 and the comparator epoetin alfa were bioequivalent at steady state circulating drug concentrations with respect to their pharmacokinetic profile and pharmacodynamic action. This supports the conclusion that HX575 and the comparator epoetin alfa, when administered intraveneously, will be equally efficacious and may be interchangeable as therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioequivalence of HX575 (recombinant human epoetin alfa) and a comparator epoetin alfa after multiple subcutaneous administrations.

AIM To compare the steady-state pharmacokinetics and pharmacodynamics (PK/PD) of two erythropoesis-stimulating agents (ESA), HX575 (Binocrit, Sandoz GmbH, Holzkirchen, Germany), human recombinant epoetin alfa approved as the first biosimilar ESA, and a comparator epoetin alfa, following multiple subcutaneous administrations. METHODS An open, randomized, parallel group study was conducted in 8...

متن کامل

Comparison of the Pharmacokinetic and Pharmacodynamic Profiles of One US-Marketed and Two European-Marketed Epoetin Alfas

BACKGROUND HX575, licensed under the brand names Binocrit®, Epoetin Alfa Hexal®, and Abseamed®, was approved in 2007 as the first biosimilar recombinant human erythropoietin alfa (epoetin alfa) in the EU using Erypo®/Eprex® as reference product. OBJECTIVES The aim of this study was to investigate the bioequivalence and potency of registered epoetin alfa products that have not been compared be...

متن کامل

HX575: established biosimilarity in the treatment of renal anemia and 10 years of clinical experience

Erythropoiesis-stimulating agents, such as recombinant human erythropoietin, are commonly used for the treatment of anemia in patients with chronic kidney disease (CKD). In 2007, HX575 (Binocrit®) became the first biosimilar epoetin alfa to be approved by the European Medicines Agency (EMA). The decision to approve a biosimilar is based on the totality of evidence obtained in a comprehensive co...

متن کامل

A novel outpatient desensitization protocol for recombinant human erythropoietin allergy in a pediatric patient

Background Recombinant human erythropoietin, such as epoetin alfa and darbepoetin alfa, is an important therapy for anemia due to chronic renal failure. Allergy to recombinant human erythropoietin and the need for desensitization are rare. Case presentation We report here a novel epoetin alfa outpatient desensitization protocol in a girl who developed delayed cutaneous hypersensitivity to sub...

متن کامل

Evaluation of the safety and immunogenicity of subcutaneous HX575 epoetin alfa in the treatment of anemia associated with chronic kidney disease in predialysis and dialysis patients

AIM To assess the safety and immunogenicity of subcutaneous (SC) HX575 (epoetin-α) in dialysis- and nondialysis-dependent adult patients with chronic kidney disease (CKD). METHODS Open-label, single-arm, multicenter study in patients (n = 416) from Germany, Italy, Poland, Romania, Russia, Turkey, and Ukraine. RESULTS Mean (standard deviation (SD)) age was 52.3 (15.8) years, all patients wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Clinical Pharmacology

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009