Novel Concepts for RF Surface Coils with Integrated Receivers
نویسنده
چکیده
Magnetic Resonance Imaging (MRI) is a powerful non-invasive reconstruction tool used primarily in the medical community to produce high quality images of the human anatomy. Surface coils are Radio Frequency (RF) systems typically deployed for receiving the MR signals. Multiple surface coils, or an array of coils, are employed to obtain a localized improvement in the signal-to-noise ratio without limiting the field of view. In this research, a novel modeling and design method for decoupling RF surface coils in a phased array is investigated. This method employs an impedance transformation interface circuit along with a high input reflection coefficient preamplifier to decouple the coil. In this research report both the theory and design methodology are discussed in detail.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملA Printed Loop Element with Integrated Capacitors and Co-Planar Shield for 7 Tesla
INTRODUCTION Shielded RF coils have been investigated since the earliest days of MRI, taking the form of the “Zabel coil” [1] a shielded transmission line coil, coils over ground planes, and more recently microstrip coils, particularly for use at high-fields [2]. Some authors have stated that RF shields are essential for 7T surface coils over 10 cm in diameter [3], and others have successfully ...
متن کاملRadiation induced currents in MRI RF coils
The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time operation of these integ...
متن کاملThe design of dedicated RF coils for mouse MR
Introduction MR imaging of mice in medical research has allowed for well controlled disease models for pharmokinetic and dynamic tests of new contrast and therapeutic agents. However, the volume of interest in mice is typically several orders of magnitude smaller than in humans, and concomitantly the number of spins that contribute to the signal in an MR exam will be substantially smaller, ther...
متن کاملFull-Wave Analysis of Planar Radiofrequency Coils and Coil Arrays with Assumed Current Distribution
For the analysis of single radiofrequency (RF) surface coils at frequencies commonly used for magnetic resonance imaging and spectroscopy, magnetostatic analysis often provides sufficiently accurate results. However, the availability of higher field whole body magnets and the widespread use of RF coil arrays have demonstrated the need for more accurate solutions. While more advanced approaches ...