Convective flow dominates aerosol delivery to the lung segments.

نویسندگان

  • C Darquenne
  • C van Ertbruggen
  • G K Prisk
چکیده

Most previous computational studies on aerosol transport in models of the central airways of the human lung have focused on deposition, rather than transport of particles through these airways to the subtended lung regions. Using a model of the bronchial tree extending from the trachea to the segmental bronchi (J Appl Physiol 98: 970-980, 2005), we predicted aerosol delivery to the lung segments. Transport of 0.5- to 10-μm-diameter particles was computed at various gravity levels (0-1.6 G) during steady inspiration (100-500 ml/s). For each condition, the normalized aerosol distribution among the lung segments was compared with the normalized flow distribution by calculating the ratio (R(i)) of the number of particles exiting each segmental bronchus i to the flow. When R(i) = 1, particle transport was directly proportional to segmental flow. Flow and particle characteristics were represented by the Stokes number (Stk) in the trachea. For Stk < 0.01, R(i) values were close to 1 and were unaffected by gravity. For Stk > 0.01, R(i) varied greatly among the different outlets (R(i) = 0.30-1.93 in normal gravity for 10-μm particles at 500 ml/s) and was affected by gravity and inertia. These data suggest that, for Stk < 0.01, ventilation defines the delivery of aerosol to lung segments and that the use of aerosol tracers is a valid technique to visualize ventilation in different parts of the lung. At higher Stokes numbers, inertia, but not gravitational sedimentation, is the second major factor affecting the transport of large particles in the lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Aerosol delivery of ferulic acid-loaded nanostructured lipid carriers: A promising treatment approach against the respiratory disorders

Introduction: Treatment of lung diseases is one of the major healthcare challenges. Ferulic acid (FA), a phenolic compound with well-established antioxidant and anti-inflammatory properties, has shown promising therapeutic potential against the pulmonary disorders; however, low bioavailability may negatively affect its efficiency. This, prompted us to incorporate FA into the nanostructured ...

متن کامل

Effect of convective stretching and folding on aerosol mixing deep in the lung, assessed by approximate entropy.

There is a surprisingly substantial amount of aerosol mixing and deposition deep in the lung, which cannot be explained by classic transport mechanisms such as streamline crossing, inertial impaction, or gravitational sedimentation with reversible acinar flow. Mixing associated with "stretch and fold" convective flow patterns can, however, be a potent source of transport. We show such patterns ...

متن کامل

Aerosol bolus dispersion in healthy subjects.

Aerosol bolus dispersion is a physiological test of lungs, which uses monodisperse submicron particles to measure intrapulmonary convective gas mixing. In this study, aerosol bolus dispersion was measured in healthy subjects in order to assess reference values for possible clinical applications, to assess the reproducibility of these values, and to identify physical and physiological factors in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 111 1  شماره 

صفحات  -

تاریخ انتشار 2011