An Assessment of the Contrast Sensitivity in Patients with Ametropic and Anisometropic Amblyopia in Achieving the Corrected Visual Acuity of 1.0
نویسندگان
چکیده
Both visual acuity (VA) and contrast sensitivity (CS) are important parameters for measuring visual function. In this research, we investigated the CS of patients with ametropic or anisometropic amblyopia, whose corrected visual acuity (CVA) recovered to 1.0. Fifty-five cases with amblyopia and 22 control cases with a normal visual acuity of 1.0 were enrolled. The CS of the patients whose ametropic amblyopia had recovered to a CVA of 1.0 at 18 cpd spatial frequency was still lower than that of the normal control group under both photopic and scotopic conditions (P = 0.001, 0.025), but there were no significant differences at low- and middle-spatial frequencies. The CS of amblyopic eyes of the patients with anisometropic amblyopia was lower than that of the normal control group at the 18 cpd spatial frequency under photopic conditions (P = 0.005), and at the 6 cpd, 12 cpd, and 18 cpd spatial frequencies under scotopic conditions (P = 0.008, <0.001, 0.004, respectively). The CS between the amblyopic eyes and the sound eyes of patients with anisometropic amblyopia presented significant differences at the 6 cpd, 12 cpd, and 18 cpd spatial frequencies under scotopic conditions (P = 0.025, 0.045, 0.019, respectively). We suggest that amblyopia treatment should involve not only the correction of VA but also the improvement of CS.
منابع مشابه
Comparison of the Wave Amplitude of Visually Evoked Potential in Amblyopic Eyes between Patients with Esotropia and Anisometropia and a Normal Group
Background: We compared the wave amplitude of visually evoked potential (VEP) between patients with esotropic and anisometropic amblyopic eyes and a normal group.Methods: The wave amplitude of VEP was documented in 2 groups of persons with amblyopia (15 with esotropia and 28 with anisometropia) and 1 group of individuals with normal visual acuity (n, 15). The amplitude of P100 was recorded mono...
متن کاملبررسی مقایسهای دو روش CAM و اکلوژن در درمان آمبلیوپی آنیزومتروپیک
Occlusion is a method that has been used in the treatment of amblyopia since before and CAM visual stimulation (CAM therapy) is other method which can be used for amblyotherapy.In this study twenty two 6-year-old, previously untreated amblyopic children were divided into two subgroups with regard to anisometropic and ametropic amounts.The first group was treated by occlusion therapy and the se...
متن کاملAdvanced Analysis of PRVEP in Anisometropic Amblyopia
Introduction: to identify the pattern-reversal visual evoked potential (PRVEP) waveform descriptor by evaluating discrete wavelet transform (DWT) in order to optimize stimulus in the diagnosis of anisometropia amblyopia. Materials and Methods: The PRVEP testing was performedfor 31 normal individuals and 35 patients with amblyopia. The stimuli were consisted of spatial frequencies of 1, 2, and 4...
متن کاملVisual Acuity Improvement in Continuous vs Divided Occlusion in Anisometropic Amblyopia
Purpose To compare visual acuity improvement between continuous and split part-time occlusion for the treatment of moderate and severe anisometropic amblyopia. Methods Randomised clinical trials in 6 - 13 y.o children with moderate and severe anisometropic amblyopia. Each patient was consecutively selected with continuous or split part-time occlusion. Best corrected visual acuity's improvemen...
متن کاملبررسی مقایسهای حدت بینایی و حساسیت به کنتراست در رانندگان مراجعهکننده به درمانگاه چشم بیمارستان فرشچیان همدان
Background and Objective: Car accidents are the second leading cause of mortality in Iran. For safe driving, drivers require minimum acceptable visual acuity. In Iran, the accepted routine test to take driving license is Snellen vision chart, which is not adequate for visual acuity determination in real and natural environment. It seems that introducing a more sensitive and specific screening t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2017