Candidates for a possible third-generation gravitational wave detector: comparison of ring- Sagnac and sloshing-Sagnac speedmeter interferometers

نویسندگان

  • Haixing Miao
  • Huan Yang
  • Rana X Adhikari
  • Giovanni Guccione
  • Harry J Slatyer
  • André R R Carvalho
چکیده

Speedmeters are known to be quantum non-demolition devices and, by potentially providing sensitivity beyond the standard quantum limit, become interesting for third generation gravitational wave detectors. Here we introduce a new configuration, the sloshing-Sagnac interferometer, and compare it to the more established ring-Sagnac interferometer. The sloshing-Sagnac interferometer is designed to provide improved quantum noise limited sensitivity and lower coating thermal noise than standard position meter interferometers employed in current gravitational wave detectors. We compare the quantum noise limited sensitivity of the ring-Sagnac and the sloshing-Sagnac interferometers, in the frequency range, from 5 Hz to 100 Hz, where they provide the greatest potential benefit. We evaluate the improvement in terms of the unweighted noise reduction below the standard quantum limit, and by finding the range up to which binary black hole inspirals may be observed. The sloshing-Sagnac was found to give approximately similar or better sensitivity than the ring-Sagnac in all cases. We also show that by eliminating the requirement for maximally-reflecting cavity end mirrors with correspondingly-thick multi-layer coatings, coating noise can be reduced by a factor of approximately 2.2 compared to conventional interferometers. S H Huttner et al Candidates for a possible third-generation gravitational wave detector: comparison of ring-Sagnac and sloshing-Sagnac speedmeter interferometers Printed in the UK 024001 CQGRDG © 2016 IOP Publishing Ltd 34 Class. Quantum Grav.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Candidates for a possible third-generation gravitational wave detector: comparison of ring- Sagnac and sloshing-Sagnac speedmeter interferometers

Speedmeters are known to be quantum non-demolition devices and, by potentially providing sensitivity beyond the standard quantum limit, become interesting for third generation gravitational wave detectors. Here we introduce a new configuration, the sloshing-Sagnac interferometer, and compare it to the more established ring-Sagnac interferometer. The sloshing-Sagnac interferometer is designed to...

متن کامل

Candidates for a possible third-generation gravitational wave detector: comparison of ring- Sagnac and sloshing-Sagnac speedmeter interferometers

Speedmeters are known to be quantum non-demolition devices and, by potentially providing sensitivity beyond the standard quantum limit, become interesting for third generation gravitational wave detectors. Here we introduce a new configuration, the sloshing-Sagnac interferometer, and compare it to the more established ring-Sagnac interferometer. The sloshing-Sagnac interferometer is designed to...

متن کامل

Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector

According to quantum measurement theory, “speed meters” — devices that measure the momentum, or speed, of free test masses — are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one igno...

متن کامل

Application of Fast Light in Gravitational Wave Detection with Interferometers and Resonators

In this paper, we study several designs for interferometric gravitational wave detectors, and the potential for enhancing their performance with a fast-light medium. First, we explore the effect of such a medium on designs similar to those already planned for Advanced LIGO. Then we review the zero-area Sagnac interferometer for GW detection, comparing its properties against the more conventiona...

متن کامل

All-reflective Michelson, Sagnac, and Fabry-Perot interferometers based on grating beam splitters.

All-reflective Michelson, Sagnac, and Fabry-Perot interferometers based on grating beam splitters are experimentally demonstrated at a wavelength of 1064 nm. A 1200-groove/mm grating diffracting 0 and -1 orders with an efficiency of 48.2% for each order was used as a near-50/50 beam splitter. The all-reflective Sagnac and Michelson interferometers were formed by reintroducing both of the diffra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016