Clinical consequences of a miscalibrated digoxin immunoassay.
نویسندگان
چکیده
BACKGROUND A routine audit revealed that the analytical method used to measure digoxin concentrations by our statewide pathology provider in 2009 was underestimating digoxin concentrations by 10%. The assay was recalibrated by the manufacturer in 2010, but clinical outcomes of the underestimation were never measured. This is a pilot study to describe the prescribing behavior around out-of-range digoxin concentrations and to assess whether miscalibrated digoxin immunoassays contribute to clinically relevant effects, as measured by inappropriate alterations in digoxin doses. METHODS About 30,000 digoxin concentrations across the State Hospital system were obtained in 2 periods before and after recalibration of the digoxin assay. Digoxin concentration means were calculated and compared and were statistically significantly different. Subsequently, a single-centered retrospective review of 50 randomly chosen charts was undertaken to study the clinical implications of the underestimated concentrations. RESULTS Mean digoxin concentrations for 2009 and 2011 were significantly different by 8.8% (confidence interval, 7.0%-10.6%). After recalculating the 2009 concentrations to their "corrected" values, there was a 16% increase in the number of concentrations within the range when compared with the 2011 concentrations (41.48% versus 48.04%). However, overall, this did not cause unnecessary dose changes in patients who were "borderline" or outside the therapeutic range when compared with controls (P = 0.10). The majority of decisions were based on the clinical impression rather than concentration alone (85.1% versus 14.9%), even when the concentration was outside the "therapeutic range." CONCLUSIONS Although recalculating digoxin concentrations measured during 2009 to their corrected values produced a significant change in concentration and values inside and outside the range, this does not seem to have had an influence on patient treatment. Rather, clinicians tended to use the clinical impression to dose digoxin.
منابع مشابه
Endogenous digoxin-like immunoreactive factors eliminated from serum samples by hydrophobic silica-gel extraction and enzyme immunoassay.
Elimination of endogenous digoxin-like immunoreactive factors (DLIF) that interfere with accurate measurement of digoxin requires use of a highly specific anti-digoxin antibody, or that DLIF be separated from digoxin before immunoassay. Several commercial digoxin-assay kits include a step for separating serum proteins and other substances from digoxin before immunoassay. We tested six different...
متن کاملCompetitive solid-phase enzyme immunoassay for measuring digoxin in serum.
In this clinically useful enzyme immunoassay of digoxin in serum, we mix sample, beta-galactosidase-labeled digoxin, and anti-digoxin Fab fragments for 30 min at room temperature, then use Sepharose-bound second antibody for phase separation, and measure the unbound enzyme activity directly in the supernate of the equilibrium reaction mixture. The immunoassay buffer--phosphate-buffered isotonic...
متن کاملEffect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.
Determination of digoxin by fluorescence polarization immunoassay (FPIA) with the Abbott "TDx" is significantly influenced by the concentration of total serum protein. Each 10 g/L increase in serum protein results in an 8% decrease in measured digoxin. Studies with [3H]digoxin confirmed that digoxin binds to the protein pellet during the trichloroacetic acid precipitation step before the immuno...
متن کاملClinical judgement perplexed by initially undisclosed use of herbal medicine and unexpected cross-reactivity of immunoassay.
We report a case of symptomatic bradycardia caused by consumption of a Chinese herbal medicine which was initially undisclosed to the attending emergency physician. The scientific name of the herb is Panax japonicus. Electrocardiogram revealed sinus bradycardia. Laboratory tests were normal except for the detection of a high serum digoxin level. Further interrogation of the patient eventually d...
متن کاملEffect of Asian and Siberian ginseng on serum digoxin measurement by five digoxin immunoassays. Significant variation in digoxin-like immunoreactivity among commercial ginsengs.
Asian and Siberian ginsengs contain glycosides with structural similarities to digoxin. We studied potential interference of ginseng in 5 digoxin immunoassays in 3 Asian (2 liquid extracts, 1 capsule) and 3 Siberian ginseng preparations (1 liquid extract, 2 capsules). With the fluorescence polarization immunoassay (FPIA), we observed apparent digoxin activity in 1 Asian liquid preparation and i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Therapeutic drug monitoring
دوره 37 1 شماره
صفحات -
تاریخ انتشار 2015